China Vacuum LOX Pipe Series

Short Description:

Vacuum Insulated Pipe (VI Piping), namely Vacuum Jacketed Pipe (VJ Piping) are used for transferring of liquid oxygen, liquid nitrogen, liquid argon, liquid hydrogen, liquid helium, LEG and LNG, as a Perfect substitute for conventional piping insulation.

Introducing China Vacuum LOX Pipe Series: Cutting-Edge Solution for Cryogenic Systems


Product Detail

Product Tags

Product Brief Description:

  • High-quality vacuum LOX pipe series designed for cryogenic applications
  • Ensures efficient and safe transfer of liquid oxygen
  • Manufactured by a leading production factory in China
  • Customizable options available to meet specific project requirements
  • Superior performance, reliability, and durability

Product Details Description:

Advanced Design and Construction:
Our China Vacuum LOX Pipe Series is meticulously engineered to meet the rigorous demands of cryogenic applications. The series features high-quality materials and advanced construction techniques, ensuring exceptional durability and performance in extreme conditions.

Efficient and Safe Liquid Oxygen Transfer:
The vacuum LOX pipe series is designed to facilitate the efficient and safe transfer of liquid oxygen within cryogenic systems. Its innovative design minimizes the risk of leaks and ensures the integrity of the oxygen transfer process, contributing to the overall safety and efficiency of the system.

Customizable Options:
Recognizing the diverse needs of different projects, our China Vacuum LOX Pipe Series offers customizable options to accommodate specific requirements. Whether it’s a particular size, material, or configuration, we can tailor the pipe series to suit individual project needs, providing a versatile solution for various applications.

Reliability and Performance:
With a focus on quality and reliability, our vacuum LOX pipe series delivers consistent performance, contributing to the overall efficiency of cryogenic systems. Its robust construction and precision engineering make it a dependable solution for critical applications, ensuring reliable operation and long-term durability.

Manufactured by a Leading Production Factory in China:
As a reputable production factory in China, we are committed to upholding the highest standards of manufacturing excellence. Our China Vacuum LOX Pipe Series is a testament to our dedication to quality, innovation, and customer satisfaction, making it the ideal choice for demanding cryogenic applications.

In conclusion, our China Vacuum LOX Pipe Series offers a cutting-edge solution for cryogenic systems, providing superior performance, reliability, and safety. With customizable options and the backing of a leading production factory in China, it is the perfect choice for a wide range of cryogenic applications.

Video

Vacuum Insulated Piping

Vacuum Insulated Pipe (VI Piping), namely Vacuum Jacketed Pipe (VJ Piping), as a Perfect substitute for conventional piping insulation. Compared with conventional piping insulation, the heat leakage value of VIP is only 0.05~0.035 times of conventional piping insulation. Significantly save energy and cost for customers.

The product series of Vacuum Jacketed Pipe, Vacuum Jacketed Hose, Vacuum Jacketed Valve, and Phase Separator in HL Cryogenic Equipment Company, which passed through a series of extremely strict technical treatments, are used for transferring of liquid oxygen, liquid nitrogen, liquid argon, liquid hydrogen, liquid helium, LEG and LNG, and these products are serviced for cryogenic equipment (e.g. cryogenic tanks, dewars and coldboxes etc.) in industries of air separation, gases, aviation, electronics, superconductor, chips, automation assembly, food & beverage, pharmacy, hospital, biobank, rubber, new material manufacturing chemical engineering, iron & steel, and scientific research etc.

Three Connection Types of VI Piping

The three connection types here apply only to the connection positions between VI pipes. When VI Pipe connects with equipment, storage tank and so on, the connection joint can be customized according to customer requirements.

In order to maximize the different needs of customers, Vacuum Insulated Pipe has developed three connection types, namely Vacuum Bayonet Connection Type with Clamps, Vacuum Bayonet Connection Type with Flanges and Bolts and Welded Connection Type. They have different advantages and are suitable for different working conditions.

Scope of Application

Vacuum Bayonet Connection Type with Clamps

Vacuum Bayonet Connection Type with Flanges and Bolts

Welded Connection Type

Connection Type

Clamps

Flanges and Bolts

Weld

Insulation Type at joints

Vacuum

Vacuum

Perlite or Vacuum

On-site Insulated Treatment

No

No

Yes, perlite filled into or vacuum pump out from the Insulated Sleeves at joints.

Nominal Diameter of Inner Pipe

DN10(3/8")~DN25(1")

DN10(3/8")~DN80(3")

DN10(3/8")~DN500(20")

Design Pressure

≤8 bar

≤16 bar

≤64 bar

Installation

Easy

Easy

Weld

Design Temperature

-196℃~ 90℃ (LH2 & LHe:-270℃ ~ 90℃)

Length

1 ~ 8.2 meter/pcs

Material

300 Series Stainless Steel

Medium

LN2, LOX, LAr, LHe, LH2, LEG, LNG

Product Scope of Supply

Product

Specification

Vacuum Bayonet Connection with Clamps

Vacuum Bayonet Connection with Flanges and Bolts

Weld Insulated Connection

Vacuum Insulated Pipe

DN8

YES

YES

YES

DN15

YES

YES

YES

DN20

YES

YES

YES

DN25

YES

YES

YES

DN32

/

YES

YES

DN40

/

YES

YES

DN50

/

YES

YES

DN65

/

YES

YES

DN80

/

YES

YES

DN100

/

/

YES

DN125

/

/

YES

DN150

/

/

YES

DN200

/

/

YES

DN250

/

/

YES

DN300

/

/

YES

DN400

/

/

YES

DN500

/

/

YES

 

Technical Characteristic

Compensator Design Pressure ≥4.0MPa
Design Temperature -196C~90℃ (LH2 & LHe:-270~90℃)
Ambient Temperature -50~90℃
Vacuum Leakage Rate ≤1*10-10Pa*m3/S
Vacuum Level after Guarantee ≤0.1 Pa
Insulated Method High Vacuum Multi-Layer Insulation.
Adsorbent and Getter Yes
NDE 100% Radiographic Examination
Test Pressure 1.15 Times Design Pressure
Medium LO2、LN2、LAr、LH2、LHe、LEG、LNG

Dynamic and Static Vacuum Insulated Piping System

Vacuum Insulated (VI) Piping System can be divided into Dynamic and Static VI Piping System.

l The Static VI Piping is fully completed in the manufacturing factory.

l The Dynamic VI Piping is offered a more stable vacuum state by a continuous pumping of vacuum pump system on site, and the rest of the assembly and process treatment is still in the manufacturing factory.

  Dynamic Vacuum Insulated Piping System Static Vacuum Insulated Piping System
Introduction The vacuum degree of the vacuum interlayer is monitored continuously, and the vacuum pump is automatically controlled to open and close, to ensure the stability and effectiveness of vacuum degree VJPs complete the vacuum insulation work in the manufacturing plant.
Advantages The vacuum retention is more stable, basically eliminate the vacuum maintenance in the future working. More economical investment and simple on-site installation
Vacuum Bayonet Connection Type with Clamps

Applicative

Applicative

Vacuum Bayonet Connection Type with Flanges and Bolts

Applicative

Applicative

Welded Connection Type

Applicative

Applicative

Dynamic Vacuum Insulated Piping System: Consist of Vacuum Insulated Pipes, Jumper Hoses and Vacuum Pump System (including the vacuum pumps, solenoid valves and vacuum gauges).

Specification and Model

HL-PX-X-000-00-X

Brand

HL Cryogenic Equipment

Description

PD: Dynamic VI Pipe

PS: Static VI Pipe

Connection Type

W: Welded Type

B: Vacuum Bayonet Type with Clamps

F: Vacuum Bayonet Type with Flanges and Bolts

Nominal Diameter of Inner Pipe

010: DN10

080: DN80

500: DN500

Design Pressure

08: 8bar
16: 16bar
25: 25bar
32: 32bar
40: 40bar

Material of Inner Pipe

A: SS304
B: SS304L
C: SS316
D: SS316L
E:Other

Static Vacuum Insulated Piping System

3.1.1 Vacuum Bayonet Connection Type with Clamps

Model

Connection Type

Nominal Diameter of Inner Pipe

Design Pressure

Material of Inner Pipe

Standard

Remark

HLPSB01008X

Vacuum Bayonet Connection Type with Clamps for Static Vacuum Insulated Piping System

DN10, 3/8"

8 bar

300 Series Stainless Steel

ASME B31.3

X:

Material of Inner Pipe.

A is 304,

B is 304L,

C is 316,

D is 316L,

E is other.

HLPSB01508X

DN15, 1/2"

HLPSB02008X

DN20, 3/4"

HLPSB02508X

DN25, 1"

Nominal Diameter of Inner Pipe: Recommended ≤ DN25 or 1". Or selects the Vacuum Bayonet Connection Type with Flanges and Bolts (from DN10, 3/8" to DN80, 3"), Welded Connection Type VIP (from DN10, 3/8" to DN500, 20")

Nominal Diameter of Outer Pipe:  Recommended by the Enterprise Standard of HL Cryogenic Equipment. It also can be produced according to requirement of the customer.

Design Pressure: Recommended ≤ 8 bar. Or selects the Vacuum Bayonet Connection Type with Flanges and Bolts (≤16 bar), Welded Connection Type (≤64 bar)

Material of Outer Pipe: Without special requirement, the material of inner pipe and outer pipe will be selected the same.

3.1.2 Vacuum Bayonet Connection Type with Flanges and Bolts

Model

Connection Type

Nominal Diameter of Inner Pipe

Design Pressure

Material of Inner Pipe

Standard

Remark

HLPSF01000X

Vacuum Bayonet Connection Type with Flanges and Bolts for Static Vacuum Insulated Piping System

DN10, 3/8"

8~16 bar

300 Series Stainless Steel

ASME B31.3

00: 

Design Pressure.

08 is 8bar,

16 is 16bar.

 

X: 

Material of Inner Pipe.

A is 304,

B is 304L,

C is 316,

D is 316L,

E is other.

HLPSF01500X

DN15, 1/2"

HLPSF02000X

DN20, 3/4"

HLPSF02500X

DN25, 1"

HLPSF03200X

DN32, 1-1/4"

HLPSF04000X

DN40, 1-1/2"

HLPSF05000X

DN50, 2"

HLPSF06500X

DN65, 2-1/2"

HLPSF08000X

DN80, 3"

Nominal Diameter of Inner Pipe: Recommended ≤ DN80 or 3". Or selects the Welded Connection Type (from DN10, 3/8" to DN500, 20"), Vacuum Bayonet Connection Type with Clamps (from DN10, 3/8" to DN25, 1").

Nominal Diameter of Outer Pipe:  Recommended by the Enterprise Standard of HL Cryogenic Equipment. It also can be produced according to requirement of the customer.

Design Pressure: Recommended ≤ 16 bar. Or selects Welded Connection Type (≤64 bar).

Material of Outer Pipe: Without special requirement, the material of inner pipe and outer pipe will be selected the same.

3.1.3 Welded Connection Type

Model

Connection Type

Nominal Diameter of Inner Pipe

Design Pressure

Material of Inner Pipe

Standard

Remark

HLPSW01000X

Welded Connection Type for Static Vacuum Insulated Piping System

DN10, 3/8"

8~64 bar

300 Series Stainless Steel

ASME B31.3

00: 

Design Pressure

08 is 8bar,

16 is 16bar,

and 25, 32, 40, 64.

 

X: 

Material of Inner Pipe.

A is 304,

B is 304L,

C is 316,

D is 316L,

E is other.

HLPSW01500X

DN15, 1/2"

HLPSW02000X

DN20, 3/4"

HLPSW02500X

DN25, 1"

HLPSW03200X

DN32, 1-1/4"

HLPSW04000X

DN40, 1-1/2"

HLPSW05000X

DN50, 2"

HLPSW06500X

DN65, 2-1/2"

HLPSW08000X

DN80, 3"

HLPSW10000X

DN100, 4"

HLPSW12500X

DN125, 5"

HLPSW15000X

DN150, 6"

HLPSW20000X

DN200, 8"

HLPSW25000X

DN250, 10"

HLPSW30000X

DN300, 12"

HLPSW35000X

DN350, 14"

HLPSW40000X

DN400, 16"

HLPSW45000X

DN450, 18"

HLPSW50000X

DN500, 20"

Nominal Diameter of Outer Pipe:  Recommended by the Enterprise Standard of HL Cryogenic Equipment. It also can be produced according to requirement of the customer.

Material of Outer Pipe: Without special requirement, the material of inner pipe and outer pipe will be selected the same.

Dynamic Vacuum Insulated Piping System

3.2.1 Vacuum Bayonet Connection Type with Clamps

Model

Connection Type

Nominal Diameter of Inner Pipe

Design Pressure

Material of Inner Pipe

Standard

Remark

HLPDB01008X

Vacuum Bayonet Connection Type with Clamps for Static Vacuum Insulated Piping System

DN10, 3/8"

8 bar

300 Series Stainless Steel

ASME B31.3

X:Material of Inner Pipe.

A is 304,

B is 304L,

C is 316,

D is 316L,

E is other.

HLPDB01508X

DN15, 1/2"

HLPDB02008X

DN20, 3/4"

HLPDB02508X

DN25, 1"

Nominal Diameter of Inner Pipe: Recommended ≤ DN25 or 1". Or selects the Vacuum Bayonet Connection Type with Flanges and Bolts (from DN10, 3/8" to DN80, 3"), Welded Connection Type VIP (from DN10, 3/8" to DN500, 20")

Nominal Diameter of Outer Pipe:  Recommended by the Enterprise Standard of HL Cryogenic Equipment. It also can be produced according to requirement of the customer.

Design Pressure: Recommended ≤ 8 bar. Or selects the Vacuum Bayonet Connection Type with Flanges and Bolts (≤16 bar), Welded Connection Type (≤64 bar)

Material of Outer Pipe: Without special requirement, the material of inner pipe and outer pipe will be selected the same.

Power Condition: The site needs to supply power to the vacuum pumps and inform HL Cryogenic Equipment the local electricity information (Voltage and Hertz)

3.2.2 Vacuum Bayonet Connection Type with Flanges and Bolts

Model

Connection Type

Nominal Diameter of Inner Pipe

Design Pressure

Material of Inner Pipe

Standard

Remark

HLPDF01000X

Vacuum Bayonet Connection Type with Flanges and Bolts for Static Vacuum Insulated Piping System

DN10, 3/8"

8~16 bar

300 Series Stainless Steel

ASME B31.3

00: Design Pressure.

08 is 8bar,

16 is 16bar.

 

X: 

Material of Inner Pipe.

A is 304,

B is 304L,

C is 316,

D is 316L,

E is other.

HLPDF01500X

DN15, 1/2"

HLPDF02000X

DN20, 3/4"

HLPDF02500X

DN25, 1"

HLPDF03200X

DN32, 1-1/4"

HLPDF04000X

DN40, 1-1/2"

HLPDF05000X

DN50, 2"

HLPDF06500X

DN65, 2-1/2"

HLPDF08000X

DN80, 3"

 

Nominal Diameter of Inner Pipe: Recommended ≤ DN80 or 3". Or selects the Welded Connection Type (from DN10, 3/8" to DN500, 20"), Vacuum Bayonet Connection Type with Clamps (from DN10, 3/8" to DN25, 1").

Nominal Diameter of Outer Pipe:  Recommended by the Enterprise Standard of HL Cryogenic Equipment. It also can be produced according to requirement of the customer.

Design Pressure: Recommended ≤ 16 bar. Or selects Welded Connection Type (≤64 bar).

Material of Outer Pipe: Without special requirement, the material of inner pipe and outer pipe will be selected the same.

Power Condition: The site needs to supply power to the vacuum pumps and inform HL Cryogenic Equipment the local electricity information (Voltage and Hertz)

3.2.3 Welded Connection Type

Model

Connection Type

Nominal Diameter of Inner Pipe

Design Pressure

Material of Inner Pipe

Standard

Remark

HLPDW01000X

Welded Connection Type for Dynamic Vacuum Insulated Piping System

DN10, 3/8"

8~64 bar

Stainless Steel 304, 304L, 316, 316L

ASME B31.3

00:

Design Pressure

08 is 8bar,

16 is 16bar,

and 25, 32, 40, 64.

.

 

X: 

Material of Inner Pipe.

A is 304,

B is 304L,

C is 316,

D is 316L,

E is other.

HLPDW01500X

DN15, 1/2"

HLPDW02000X

DN20, 3/4"

HLPDW02500X

DN25, 1"

HLPDW03200X

DN32, 1-1/4"

HLPDW04000X

DN40, 1-1/2"

HLPDW05000X

DN50, 2"

HLPDW06500X

DN65, 2-1/2"

HLPDW08000X

DN80, 3"

HLPDW10000X

DN100, 4"

HLPDW12500X

DN125, 5"

HLPDW15000X

DN150, 6"

HLPDW20000X

DN200, 8"

HLPDW25000X

DN250, 10"

HLPDW30000X

DN300, 12"

HLPDW35000X

DN350, 14"

HLPDW40000X

DN400, 16"

HLPDW45000X

DN450, 18"

HLPDW50000X

DN500, 20"

Nominal Diameter of Outer Pipe:  Recommended by the Enterprise Standard of HL Cryogenic Equipment. It also can be produced according to requirement of the customer.

Material of Outer Pipe: Without special requirement, the material of inner pipe and outer pipe will be selected the same.

Power Condition: The site needs to supply power to the vacuum pumps and inform HL Cryogenic Equipment the local electricity information (Voltage and Hertz)


  • Previous: