China Vacuum LOX Shut-off Valve

Short Description:

The Vacuum Insulated Shut-off Valve is responsible for controlling the opening and closing of Vacuum Insulated Piping. Cooperate with other products of the VI valve series to achieve more functions.

Title: Introducing China Vacuum LOX Shut-off Valve: Enhancing Safety and Efficiency


Product Detail

Product Tags

Product Brief Description:

  • High-quality shut-off valve designed for vacuum LOX applications
  • Ensures safe and efficient operation in industrial settings
  • Manufactured by a leading production factory in China
  • Designed to meet stringent industry standards
  • Provides reliable performance and long-term durability

Product Details Description:

Reliable Safety Features:
Our China Vacuum LOX Shut-off Valve is equipped with advanced safety features to prevent leaks and ensure the secure handling of liquid oxygen. The valve is designed to withstand extreme temperatures and harsh operating conditions, making it an ideal choice for industrial applications where safety is paramount.

Efficient Performance:
With a focus on efficiency, our shut-off valve is engineered to deliver smooth and precise operation, allowing for seamless control of the flow of liquid oxygen. This ensures that the valve can effectively meet the demands of various industrial processes, contributing to overall operational efficiency and productivity.

Robust Construction:
Constructed from high-quality materials, our shut-off valve is built to withstand the rigors of industrial use. Its robust design and durable components ensure long-term reliability, reducing the need for frequent maintenance and replacement. This not only saves on operational costs but also minimizes downtime, contributing to uninterrupted production processes.

Stringent Quality Standards:
At our production factory in China, we adhere to stringent quality control measures to ensure that every China Vacuum LOX Shut-off Valve meets the highest industry standards. Our commitment to quality and precision manufacturing is reflected in the performance and reliability of our products, providing our customers with peace of mind and confidence in their operations.

Customization Options:
Recognizing that different industrial applications may have unique requirements, we offer customization options for our shut-off valves. Whether it’s specific sizing, materials, or additional features, we work closely with our customers to tailor our products to their exact needs, ensuring optimal performance and compatibility with their systems.

Conclusion:
In conclusion, our China Vacuum LOX Shut-off Valve is a testament to our dedication to providing high-quality, reliable, and safe industrial equipment. With a focus on safety, efficiency, and durability, our shut-off valve is a valuable asset for industrial operations that rely on the secure handling of liquid oxygen. Backed by our commitment to quality and customer satisfaction, we are proud to offer a product that meets the diverse needs of our clients while upholding the highest industry standards.

Product Application

The product series of Vacuum Valve, Vacuum Pipe, Vacuum Hose and Phase Separator in HL Cryogenic Equipment Company, which passed through a series of extremely strict technical treatments, are used for transferring of liquid oxygen, liquid nitrogen, liquid argon, liquid hydrogen, liquid helium, LEG and LNG, and these products are serviced for cryogenic equipment (e.g. cryogenic tanks, dewars and coldboxes etc.) in industries of air separation, gases, aviation, electronics, superconductor, chips, pharmacy, biobank, food & beverage, automation assembly, chemical engineering, iron & steel, and scientific research etc.

Vacuum Insulated Shut-off Valve

The Vacuum Insulated Shut-off / Stop Valve, namely Vacuum Jacketed Shut-off Valve, is the most widely used for VI valve series in the VI Piping and VI Hose System. It is responsible for controlling the opening and closing of main and branch pipelines. Cooperate with other products of the VI valve series to achieve more functions.

In the vacuum jacketed piping system, the most cold loss is from the cryogenic valve on the pipeline. Because there is no vacuum insulation but conventional insulation, the cold loss capacity of a cryogenic valve is far more than that of a vacuum jacketed piping of dozens of meters. So there are often customers who chose the vacuum jacketed piping, but the cryogenic valves on both ends of the pipeline choose the conventional insulation, which still leads to huge cold losses.

The VI Shut-off Valve, simply speaking, is put a vacuum jacket on the cryogenic valve, and with its ingenious structure it achieves the minimum cold loss. In the manufacturing plant, VI Shut-off Valve and VI Pipe or Hose are prefabricated into one pipeline, and there is no need for installation and insulated treatment on site. For maintenance, the seal unit of VI Shut-off Valve can be replaced easily without damaging its vacuum chamber.

The VI Shut-off Valve has a variety of connectors and couplings to meet different situations. At the same time, the connector and coupling can be customized according to customer requirements.

HL accepts the cryogenic valve brand designated by customers, and then makes vacuum insulated valves by HL. Some brands and models of valves may not be able to be made into vacuum insulated valves.

About VI valve series more detailed and personalized questions, please contact HL cryogenic equipment directly, we will serve you wholeheartedly!

Parameter Information

Model HLVS000 Series
Name Vacuum Insulated Shut-off Valve
Nominal Diameter DN15 ~ DN150 (1/2" ~ 6")
Design Pressure ≤64bar (6.4MPa)
Design Temperature -196℃~ 60℃ (LH2 & LHe:-270℃ ~ 60℃)
Medium LN2, LOX, LAr, LHe, LH2, LNG
Material Stainless Steel 304 / 304L / 316 / 316L
On-site Installation No
On-site Insulated Treatment No

HLVS000 Series, 000 represents the nominal diameter, such as 025 is DN25 1" and 100 is DN100 4".


  • Previous:
  • Next:

  • Leave Your Message