Liquid Helium Filter

Short Description:

Vacuum Jacketed Filter is used to filter impurities and possible ice residue from liquid nitrogen storage tanks.

  • Superior Filtration Efficiency: Our Liquid Helium Filters leverage advanced filtration technology to effectively remove impurities, particles, and contaminants from liquid helium. This ensures the integrity and purity of the helium, minimizing potential damage to cryogenic systems and improving overall performance.
  • Exceptional Flow Rates: With optimized design and engineering, our filters provide high flow rates, allowing for efficient helium filtration without compromising system productivity. The enhanced flow rates contribute to swift filtration processes and increased throughput in cryogenic applications.
  • Reliable and Durable Construction: Our Liquid Helium Filters are constructed with high-quality materials that are resistant to cryogenic temperatures and corrosion. This ensures long-term reliability and durability, even in extreme conditions, prolonging the lifespan of the filter and reducing maintenance requirements.
  • Customized Solutions: We understand the diverse needs of different cryogenic systems. Therefore, our Liquid Helium Filters can be customized based on specifications such as size, filtration level, and compatibility with specific applications. This flexibility allows for seamless integration into various cryogenic setups.
  • Expert Technical Support: As a reputable manufacturing factory, we provide comprehensive technical support and guidance throughout the filter selection and installation processes. Our team of experts is dedicated to assisting customers in choosing the most suitable Liquid Helium Filters for their specific cryogenic requirements.

Product Detail

Product Tags

Superior Filtration Efficiency: Our Liquid Helium Filters are equipped with advanced filtration media, engineered to capture impurities and particles efficiently. This filtration process ensures the purity of liquid helium, safeguarding cryogenic systems from potential damage and ensuring optimal performance.

Exceptional Flow Rates: Designed with flow optimization in mind, our filters offer superior flow rates that facilitate quick and efficient filtration processes. This enables cryogenic systems to operate at their full potential, enhancing productivity and overall system efficiency.

Reliable and Durable Construction: Our Liquid Helium Filters are meticulously crafted from materials that can withstand cryogenic temperatures and resist corrosion. The robust construction ensures reliable and durable performance, making our filters suitable for long-term use in demanding cryogenic environments.

Customized Solutions: We recognize that every cryogenic system has unique requirements. Hence, we offer customization options for our Liquid Helium Filters, allowing customers to select the appropriate size, filtration level, and compatibility to perfectly integrate the filters into their specific applications.

Expert Technical Support: Our experienced team of engineers and technical professionals is committed to providing reliable technical support to our customers. We offer guidance on selecting the most suitable Liquid Helium Filters, ensuring smooth installation, and addressing any queries or concerns promptly.

Product Application

The all series of vacuum insulated equipment in HL Cryogenic Equipment Company, which passed through a series of extremely strict technical treatments, are used for transferring of liquid oxygen, liquid nitrogen, liquid argon, liquid hydrogen, liquid helium, LEG and LNG, and these products are serviced for cryogenic equipment (cryogenic tanks and dewar flasks etc.) in industries of air separation, gases, aviation, electronics, superconductor, chips, pharmacy, hospital, biobank, food & beverage, automation assembly, rubber, new material manufacturing and scientific research etc.

Vacuum Insulated Filter

The Vacuum Insulated Filter, namely Vacuum Jacketed Filter, is used to filter impurities and possible ice residue from liquid nitrogen storage tanks.

The VI Filter can effectively prevent the damage caused by impurities and ice residue to the terminal equipment, and improve the service life of the terminal equipment. In particular, it is strongly recommend for high value terminal equipment.

The VI Filter is installed in front of main line of VI pipeline. In the manufacturing plant, the VI Filter and VI Pipe or Hose are prefabricated into one pipeline, and there is no need for installation and insulated treatment on site.

The reason why the ice slag appears in the storage tank and vacuum jacketed piping is that when the cryogenic liquid is filled at the first time, the air in the storage tanks or VJ piping is not exhausted in advance, and the moisture in the air freezes when it gets cryogenic liquid. Therefore, it is highly recommended to purge the VJ piping for the first time or for the recovery of the VJ piping when it is injected with cryogenic liquid. Purge can also effectively remove the impurities deposited inside the pipeline. However, installing a vacuum insulated filter is a better option and double safe measure.

For more personalized and detailed questions, please contact HL Cryogenic Equipment Company directly, we will serve you whole-heartedly!

Parameter Information

Model HLEF000 Series
Nominal Diameter DN15 ~ DN150 (1/2" ~ 6")
Design Pressure ≤40bar (4.0MPa)
Design Temperature 60℃ ~ -196℃
Medium LN2
Material 300 Series Stainless Steel
On-site Installation No
On-site Insulated Treatment No

  • Previous: