Liquid Oxygen Pipe Series
Introduction: As a renowned manufacturing factory, we specialize in producing high-quality products that cater to the needs of various industries. Our Liquid Oxygen Pipe Series offers a comprehensive solution for efficient and safe distribution of liquid oxygen. This product description will provide an overview of the key features, advantages, and technical details of our Liquid Oxygen Pipe Series, helping you make an informed decision.
Product Highlights:
- Seamless Gas Distribution: Our Liquid Oxygen Pipe Series ensures a smooth and uninterrupted flow of liquid oxygen, minimizing interruptions in operations.
- High Durability: Crafted with robust materials, our pipes are designed to withstand extreme temperature and pressure conditions, guaranteeing their longevity.
- Easier Installation: Our pipes feature user-friendly installation mechanisms, saving time and effort during setup.
- Customizable Options: We offer a range of sizes and configurations within our Liquid Oxygen Pipe Series, ensuring compatibility with your unique requirements.
- Stringent Quality Control: We adhere to strict quality control measures, ensuring that all our pipes pass rigorous testing for optimal performance and safety.
Product Details:
- Seamless Gas Distribution: Our Liquid Oxygen Pipe Series is engineered to provide seamless gas distribution, enabling efficient and reliable supply across various applications. With our pipes, you can ensure a constant and uninterrupted flow of liquid oxygen, reducing downtime and enhancing productivity.
- High Durability and Safety: Built with durable materials, our pipes are capable of withstanding extreme temperature fluctuations and high pressure. This makes them highly reliable and safe for long-term use. Additionally, our pipes are designed with safety in mind, minimizing the risk of leaks or accidents during the transportation and distribution of liquid oxygen.
- Easy Installation and Maintenance: Our Liquid Oxygen Pipe Series is designed for easy installation, saving time and effort during setup. The pipes are equipped with user-friendly connectors, allowing for quick and hassle-free integration into your existing systems. Furthermore, our pipes require minimal maintenance, reducing operational disruptions and optimizing productivity.
- Customizable Options: We offer a range of sizes and configurations within our Liquid Oxygen Pipe Series, ensuring compatibility with a wide range of applications. Our expert team can assist in selecting the most suitable options based on your specific requirements.
In summary, our Liquid Oxygen Pipe Series delivers efficient and safe gas distribution solutions. With its seamless gas distribution, high durability, easy installation and maintenance, and customization options, our pipe series perfectly caters to diverse industrial needs. Choose our Liquid Oxygen Pipe Series to optimize your liquid oxygen distribution system with reliability and enhanced efficiency.
Video
Vacuum Insulated Piping
Vacuum Insulated Pipe (VI Piping), namely Vacuum Jacketed Pipe (VJ Piping), as a Perfect substitute for conventional piping insulation. Compared with conventional piping insulation, the heat leakage value of VIP is only 0.05~0.035 times of conventional piping insulation. Significantly save energy and cost for customers.
The product series of Vacuum Jacketed Pipe, Vacuum Jacketed Hose, Vacuum Jacketed Valve, and Phase Separator in HL Cryogenic Equipment Company, which passed through a series of extremely strict technical treatments, are used for transferring of liquid oxygen, liquid nitrogen, liquid argon, liquid hydrogen, liquid helium, LEG and LNG, and these products are serviced for cryogenic equipment (e.g. cryogenic tanks, dewars and coldboxes etc.) in industries of air separation, gases, aviation, electronics, superconductor, chips, automation assembly, food & beverage, pharmacy, hospital, biobank, rubber, new material manufacturing chemical engineering, iron & steel, and scientific research etc.
Three Connection Types of VI Piping
The three connection types here apply only to the connection positions between VI pipes. When VI Pipe connects with equipment, storage tank and so on, the connection joint can be customized according to customer requirements.
In order to maximize the different needs of customers, Vacuum Insulated Pipe has developed three connection types, namely Vacuum Bayonet Connection Type with Clamps, Vacuum Bayonet Connection Type with Flanges and Bolts and Welded Connection Type. They have different advantages and are suitable for different working conditions.
Scope of Application
Vacuum Bayonet Connection Type with Clamps |
Vacuum Bayonet Connection Type with Flanges and Bolts |
Welded Connection Type |
|
Connection Type |
Clamps |
Flanges and Bolts |
Weld |
Insulation Type at joints |
Vacuum |
Vacuum |
Perlite or Vacuum |
On-site Insulated Treatment |
No |
No |
Yes, perlite filled into or vacuum pump out from the Insulated Sleeves at joints. |
Nominal Diameter of Inner Pipe |
DN10(3/8")~DN25(1") |
DN10(3/8")~DN80(3") |
DN10(3/8")~DN500(20") |
Design Pressure |
≤8 bar |
≤16 bar |
≤64 bar |
Installation |
Easy |
Easy |
Weld |
Design Temperature |
-196℃~ 90℃ (LH2 & LHe:-270℃ ~ 90℃) |
||
Length |
1 ~ 8.2 meter/pcs |
||
Material |
300 Series Stainless Steel |
||
Medium |
LN2, LOX, LAr, LHe, LH2, LEG, LNG |
Product Scope of Supply
Product |
Specification |
Vacuum Bayonet Connection with Clamps |
Vacuum Bayonet Connection with Flanges and Bolts |
Weld Insulated Connection |
Vacuum Insulated Pipe |
DN8 |
YES |
YES |
YES |
DN15 |
YES |
YES |
YES |
|
DN20 |
YES |
YES |
YES |
|
DN25 |
YES |
YES |
YES |
|
DN32 |
/ |
YES |
YES |
|
DN40 |
/ |
YES |
YES |
|
DN50 |
/ |
YES |
YES |
|
DN65 |
/ |
YES |
YES |
|
DN80 |
/ |
YES |
YES |
|
DN100 |
/ |
/ |
YES |
|
DN125 |
/ |
/ |
YES |
|
DN150 |
/ |
/ |
YES |
|
DN200 |
/ |
/ |
YES |
|
DN250 |
/ |
/ |
YES |
|
DN300 |
/ |
/ |
YES |
|
DN400 |
/ |
/ |
YES |
|
DN500 |
/ |
/ |
YES |
Technical Characteristic
Compensator Design Pressure | ≥4.0MPa |
Design Temperature | -196C~90℃ (LH2 & LHe:-270~90℃) |
Ambient Temperature | -50~90℃ |
Vacuum Leakage Rate | ≤1*10-10Pa*m3/S |
Vacuum Level after Guarantee | ≤0.1 Pa |
Insulated Method | High Vacuum Multi-Layer Insulation. |
Adsorbent and Getter | Yes |
NDE | 100% Radiographic Examination |
Test Pressure | 1.15 Times Design Pressure |
Medium | LO2、LN2、LAr、LH2、LHe、LEG、LNG |
Dynamic and Static Vacuum Insulated Piping System
Vacuum Insulated (VI) Piping System can be divided into Dynamic and Static VI Piping System.
l The Static VI Piping is fully completed in the manufacturing factory.
l The Dynamic VI Piping is offered a more stable vacuum state by a continuous pumping of vacuum pump system on site, and the rest of the assembly and process treatment is still in the manufacturing factory.
Dynamic Vacuum Insulated Piping System | Static Vacuum Insulated Piping System | |
Introduction | The vacuum degree of the vacuum interlayer is monitored continuously, and the vacuum pump is automatically controlled to open and close, to ensure the stability and effectiveness of vacuum degree | VJPs complete the vacuum insulation work in the manufacturing plant. |
Advantages | The vacuum retention is more stable, basically eliminate the vacuum maintenance in the future working. | More economical investment and simple on-site installation |
Vacuum Bayonet Connection Type with Clamps |
Applicative |
Applicative |
Vacuum Bayonet Connection Type with Flanges and Bolts |
Applicative |
Applicative |
Welded Connection Type |
Applicative |
Applicative |
Dynamic Vacuum Insulated Piping System: Consist of Vacuum Insulated Pipes, Jumper Hoses and Vacuum Pump System (including the vacuum pumps, solenoid valves and vacuum gauges).
Specification and Model
HL-PX-X-000-00-X
Brand
HL Cryogenic Equipment
Description
PD: Dynamic VI Pipe
PS: Static VI Pipe
Connection Type
W: Welded Type
B: Vacuum Bayonet Type with Clamps
F: Vacuum Bayonet Type with Flanges and Bolts
Nominal Diameter of Inner Pipe
010: DN10
…
080: DN80
…
500: DN500
Design Pressure
08: 8bar
16: 16bar
25: 25bar
32: 32bar
40: 40bar
Material of Inner Pipe
A: SS304
B: SS304L
C: SS316
D: SS316L
E:Other
Static Vacuum Insulated Piping System
Model |
Connection Type |
Nominal Diameter of Inner Pipe |
Design Pressure |
Material of Inner Pipe |
Standard |
Remark |
HLPSB01008X |
Vacuum Bayonet Connection Type with Clamps for Static Vacuum Insulated Piping System |
DN10, 3/8" |
8 bar
|
300 Series Stainless Steel |
ASME B31.3 |
X:
Material of Inner Pipe. A is 304, B is 304L, C is 316, D is 316L, E is other. |
HLPSB01508X |
DN15, 1/2" |
|||||
HLPSB02008X |
DN20, 3/4" |
|||||
HLPSB02508X |
DN25, 1" |
Nominal Diameter of Inner Pipe: Recommended ≤ DN25 or 1". Or selects the Vacuum Bayonet Connection Type with Flanges and Bolts (from DN10, 3/8" to DN80, 3"), Welded Connection Type VIP (from DN10, 3/8" to DN500, 20")
Nominal Diameter of Outer Pipe: Recommended by the Enterprise Standard of HL Cryogenic Equipment. It also can be produced according to requirement of the customer.
Design Pressure: Recommended ≤ 8 bar. Or selects the Vacuum Bayonet Connection Type with Flanges and Bolts (≤16 bar), Welded Connection Type (≤64 bar)
Material of Outer Pipe: Without special requirement, the material of inner pipe and outer pipe will be selected the same.
Model |
Connection Type |
Nominal Diameter of Inner Pipe |
Design Pressure |
Material of Inner Pipe |
Standard |
Remark |
HLPSF01000X |
Vacuum Bayonet Connection Type with Flanges and Bolts for Static Vacuum Insulated Piping System |
DN10, 3/8" |
8~16 bar |
300 Series Stainless Steel |
ASME B31.3 |
00:
Design Pressure. 08 is 8bar, 16 is 16bar.
X: Material of Inner Pipe. A is 304, B is 304L, C is 316, D is 316L, E is other. |
HLPSF01500X |
DN15, 1/2" |
|||||
HLPSF02000X |
DN20, 3/4" |
|||||
HLPSF02500X |
DN25, 1" |
|||||
HLPSF03200X |
DN32, 1-1/4" |
|||||
HLPSF04000X |
DN40, 1-1/2" |
|||||
HLPSF05000X |
DN50, 2" |
|||||
HLPSF06500X |
DN65, 2-1/2" |
|||||
HLPSF08000X |
DN80, 3" |
Nominal Diameter of Inner Pipe: Recommended ≤ DN80 or 3". Or selects the Welded Connection Type (from DN10, 3/8" to DN500, 20"), Vacuum Bayonet Connection Type with Clamps (from DN10, 3/8" to DN25, 1").
Nominal Diameter of Outer Pipe: Recommended by the Enterprise Standard of HL Cryogenic Equipment. It also can be produced according to requirement of the customer.
Design Pressure: Recommended ≤ 16 bar. Or selects Welded Connection Type (≤64 bar).
Material of Outer Pipe: Without special requirement, the material of inner pipe and outer pipe will be selected the same.
Model |
Connection Type |
Nominal Diameter of Inner Pipe |
Design Pressure |
Material of Inner Pipe |
Standard |
Remark |
HLPSW01000X |
Welded Connection Type for Static Vacuum Insulated Piping System |
DN10, 3/8" |
8~64 bar |
300 Series Stainless Steel |
ASME B31.3 |
00:
Design Pressure 08 is 8bar, 16 is 16bar, and 25, 32, 40, 64.
X: Material of Inner Pipe. A is 304, B is 304L, C is 316, D is 316L, E is other. |
HLPSW01500X |
DN15, 1/2" |
|||||
HLPSW02000X |
DN20, 3/4" |
|||||
HLPSW02500X |
DN25, 1" |
|||||
HLPSW03200X |
DN32, 1-1/4" |
|||||
HLPSW04000X |
DN40, 1-1/2" |
|||||
HLPSW05000X |
DN50, 2" |
|||||
HLPSW06500X |
DN65, 2-1/2" |
|||||
HLPSW08000X |
DN80, 3" |
|||||
HLPSW10000X |
DN100, 4" |
|||||
HLPSW12500X |
DN125, 5" |
|||||
HLPSW15000X |
DN150, 6" |
|||||
HLPSW20000X |
DN200, 8" |
|||||
HLPSW25000X |
DN250, 10" |
|||||
HLPSW30000X |
DN300, 12" |
|||||
HLPSW35000X |
DN350, 14" |
|||||
HLPSW40000X |
DN400, 16" |
|||||
HLPSW45000X |
DN450, 18" |
|||||
HLPSW50000X |
DN500, 20" |
Nominal Diameter of Outer Pipe: Recommended by the Enterprise Standard of HL Cryogenic Equipment. It also can be produced according to requirement of the customer.
Material of Outer Pipe: Without special requirement, the material of inner pipe and outer pipe will be selected the same.
Dynamic Vacuum Insulated Piping System
Model |
Connection Type |
Nominal Diameter of Inner Pipe |
Design Pressure |
Material of Inner Pipe |
Standard |
Remark |
HLPDB01008X |
Vacuum Bayonet Connection Type with Clamps for Static Vacuum Insulated Piping System |
DN10, 3/8" |
8 bar |
300 Series Stainless Steel |
ASME B31.3 |
X:Material of Inner Pipe.
A is 304, B is 304L, C is 316, D is 316L, E is other. |
HLPDB01508X |
DN15, 1/2" |
|||||
HLPDB02008X |
DN20, 3/4" |
|||||
HLPDB02508X |
DN25, 1" |
Nominal Diameter of Inner Pipe: Recommended ≤ DN25 or 1". Or selects the Vacuum Bayonet Connection Type with Flanges and Bolts (from DN10, 3/8" to DN80, 3"), Welded Connection Type VIP (from DN10, 3/8" to DN500, 20")
Nominal Diameter of Outer Pipe: Recommended by the Enterprise Standard of HL Cryogenic Equipment. It also can be produced according to requirement of the customer.
Design Pressure: Recommended ≤ 8 bar. Or selects the Vacuum Bayonet Connection Type with Flanges and Bolts (≤16 bar), Welded Connection Type (≤64 bar)
Material of Outer Pipe: Without special requirement, the material of inner pipe and outer pipe will be selected the same.
Power Condition: The site needs to supply power to the vacuum pumps and inform HL Cryogenic Equipment the local electricity information (Voltage and Hertz)
Model |
Connection Type |
Nominal Diameter of Inner Pipe |
Design Pressure |
Material of Inner Pipe |
Standard |
Remark |
HLPDF01000X |
Vacuum Bayonet Connection Type with Flanges and Bolts for Static Vacuum Insulated Piping System |
DN10, 3/8" |
8~16 bar |
300 Series Stainless Steel |
ASME B31.3 |
00: Design Pressure.
08 is 8bar, 16 is 16bar.
X: Material of Inner Pipe. A is 304, B is 304L, C is 316, D is 316L, E is other. |
HLPDF01500X |
DN15, 1/2" |
|||||
HLPDF02000X |
DN20, 3/4" |
|||||
HLPDF02500X |
DN25, 1" |
|||||
HLPDF03200X |
DN32, 1-1/4" |
|||||
HLPDF04000X |
DN40, 1-1/2" |
|||||
HLPDF05000X |
DN50, 2" |
|||||
HLPDF06500X |
DN65, 2-1/2" |
|||||
HLPDF08000X |
DN80, 3" |
Nominal Diameter of Inner Pipe: Recommended ≤ DN80 or 3". Or selects the Welded Connection Type (from DN10, 3/8" to DN500, 20"), Vacuum Bayonet Connection Type with Clamps (from DN10, 3/8" to DN25, 1").
Nominal Diameter of Outer Pipe: Recommended by the Enterprise Standard of HL Cryogenic Equipment. It also can be produced according to requirement of the customer.
Design Pressure: Recommended ≤ 16 bar. Or selects Welded Connection Type (≤64 bar).
Material of Outer Pipe: Without special requirement, the material of inner pipe and outer pipe will be selected the same.
Power Condition: The site needs to supply power to the vacuum pumps and inform HL Cryogenic Equipment the local electricity information (Voltage and Hertz)
Model |
Connection Type |
Nominal Diameter of Inner Pipe |
Design Pressure |
Material of Inner Pipe |
Standard |
Remark |
HLPDW01000X |
Welded Connection Type for Dynamic Vacuum Insulated Piping System |
DN10, 3/8" |
8~64 bar |
Stainless Steel 304, 304L, 316, 316L |
ASME B31.3 |
00:
Design Pressure 08 is 8bar, 16 is 16bar, and 25, 32, 40, 64. .
X: Material of Inner Pipe. A is 304, B is 304L, C is 316, D is 316L, E is other. |
HLPDW01500X |
DN15, 1/2" |
|||||
HLPDW02000X |
DN20, 3/4" |
|||||
HLPDW02500X |
DN25, 1" |
|||||
HLPDW03200X |
DN32, 1-1/4" |
|||||
HLPDW04000X |
DN40, 1-1/2" |
|||||
HLPDW05000X |
DN50, 2" |
|||||
HLPDW06500X |
DN65, 2-1/2" |
|||||
HLPDW08000X |
DN80, 3" |
|||||
HLPDW10000X |
DN100, 4" |
|||||
HLPDW12500X |
DN125, 5" |
|||||
HLPDW15000X |
DN150, 6" |
|||||
HLPDW20000X |
DN200, 8" |
|||||
HLPDW25000X |
DN250, 10" |
|||||
HLPDW30000X |
DN300, 12" |
|||||
HLPDW35000X |
DN350, 14" |
|||||
HLPDW40000X |
DN400, 16" |
|||||
HLPDW45000X |
DN450, 18" |
|||||
HLPDW50000X |
DN500, 20" |
Nominal Diameter of Outer Pipe: Recommended by the Enterprise Standard of HL Cryogenic Equipment. It also can be produced according to requirement of the customer.
Material of Outer Pipe: Without special requirement, the material of inner pipe and outer pipe will be selected the same.
Power Condition: The site needs to supply power to the vacuum pumps and inform HL Cryogenic Equipment the local electricity information (Voltage and Hertz)