HL Cryogenic Equipment’s vacuum jacketed valves, vacuum jacketed pipe, vacuum jacketed hoses and phase separators are processed through a series of extremely rigorous processes for the transport of liquid oxygen, liquid nitrogen, liquid argon, liquid hydrogen, liquid helium, LEG and LNG, and these products are serviced for cryogenic equipment (e.g. cryogenic tanks and dewars etc.) in industries of air separation, gases, aviation, electronics, superconductor, chips, pharmacy, cellbank, food & beverage, automation assembly, rubber products and scientific research etc.
Vacuum Insulated Pneumatic Shut-off Valve
The Vacuum Insulated Pneumatic Shut-off Valve, namely Vacuum Jacketed Pneumatic Shut-off Valve, is one of the common series of VI Valve. Pneumatically controlled Vacuum Insulated Shut-off / Stop Valve to control the opening and closing of main and branch pipelines. It is a good choice when it is necessary to cooperate with PLC for automatic control or when the valve position is not convenient for personnel to operate.
The VI Pneumatic Shut-off Valve / Stop Valve, simply speaking, is put a vacuum jacket on the cryogenic Shut-off Valve / Stop valve and added a set of cylinder system. In the manufacturing plant, VI Pneumatic Shut-off Valve and the VI Pipe or Hose are prefabricated into one pipeline, and there is no need for installation with pipeline and insulated treatment on site.
The VI Pneumatic Shut-off Valve can be connected with PLC system, with more other equipment, to achieve more automatic control functions.
Pneumatic or electric actuators can be used to automate the operation of the VI Pneumatic shut-off Valve.
About VI valve series more detailed and personalized questions, please contact HL cryogenic equipment directly, we will serve you wholeheartedly!
Parameter Information
Model | HLVSP000 Series |
Name | Vacuum Insulated Pneumatic Shut-off Valve |
Nominal Diameter | DN15 ~ DN150 (1/2″ ~ 6″) |
Design Pressure | ≤40bar (4.0MPa) |
Design Temperature | -196℃~ 60℃ (LH2 & LHe:-270℃ ~ 60℃) |
Cylinder Pressure | 3bar ~ 14bar (0.3 ~ 1.4MPa) |
Medium | LN2, LOX, LAr, LHe, LH2, LNG |
Material | Stainless Steel 304 |
On-site Installation | No, connect to air source. |
On-site Insulated Treatment | No |
HLVSP000 Series, 000 represents the nominal diameter, such as 025 is DN25 1″ and 100 is DN100 4″.
Product detail pictures:
Related Product Guide:
Innovation, good quality and reliability are the core values of our enterprise. These principles today extra than ever form the basis of our success as an internationally active mid-size organization for OEM/ODM China Cryogenic Valve - Vacuum Insulated Pneumatic Shut-off Valve – Holy , The product will supply to all over the world, such as: Liverpool, Azerbaijan, Iraq, We believe that good business relationships will lead to mutual benefits and improvement for both parties. We have established long-term and successful cooperative relationships with many customers through their confidence in our customized services and integrity in doing business. We also enjoy a high reputation through our good performance. Better performance will be expected as our principle of integrity. Devotion and Steadiness will remain as ever.