Vacuum Flexible Hose Series
Video
Vacuum Insulated Piping
Vacuum Insulated Hose (vacuum hose), namely Vacuum Jacketed Hose, as a Perfect substitute for conventional piping insulation. Compared with conventional piping insulation, the heat leakage value of VIP is only 0.05~0.035 times of conventional piping insulation. Significantly save energy and cost for customers.
The product series of Vacuum Insulated Hose, Vacuum Insulated Pipe, Vacuum Insulated Valve, and Phase Separator in HL Cryogenic Equipment Company, which passed through a series of extremely strict technical treatments, are used for transferring of liquid oxygen, liquid nitrogen, liquid argon, liquid hydrogen, liquid helium, LEG and LNG, and these products are serviced for cryogenic equipment (e.g. cryogenic tank, dewar and coldbox etc.) in industries of air separation, gases, aviation, electronics, superconductor, chips, pharmacy, hospital, biobank, food & beverage, automation assembly, rubber, new material manufacturing chemical engineering, iron & steel, and scientific research etc.
1.1 Four Connection Types
In order to maximize the different needs of customers, there are usually four connection types for VI Flexible Hose. The first three connection types apply only to the connection positions between VI Flexible Hoses. The fourth one, threaded connection type is generally used only for VI Hose connections to equipment and storage tank.
When VI Flexible Hose connects with equipment, storage tank and so on, the connection joint can be customized according to customer requirements.
Scope of Application
Vacuum Bayonet Connection Type with Clamps |
Vacuum Bayonet Connection Type with Flanges and Bolts |
Welded Connection Type |
Thread Joint Connection Type |
|
Connection Type |
Clamps |
Flanges and Bolts |
Weld |
Thread |
Insulation Type at joints |
Vacuum |
Vacuum |
Perlite or Vacuum |
Wrapping Insulated Materials |
On-site Insulated Treatment |
No |
No |
Yes, perlite filled into or vacuum pump out from the Insulated Sleeves at joints. |
Yes |
Nominal Diameter of Inner Pipe |
DN10(3/8")~DN25(1") |
DN10(3/8")~DN80(3") |
DN10(3/8")~DN150(6") |
DN10(3/8")~DN25(1") |
Design Pressure |
≤8 bar |
≤16 bar |
≤40 bar |
≤16 bar |
Installation |
Easy |
Easy |
Weld |
Easy |
Design Temperature |
-196℃~ 60℃ (LH2 & LHe:-270℃ ~ 60℃) |
|||
Length |
≥ 1 meter/pcs |
|||
Material |
300 Series Stainless Steel |
|||
Medium |
LN2, LOX, LAr, LHe, LH2, LNG |
1.2 Dynamic and Static Vacuum Insulated Flexible Hose
Vacuum Insulated (VI) Flexible Hose can be divided into Dynamic and Static VI Flexible Hose.
l The Static VI Hose is fully completed in the manufacturing factory.
l The Dynamic VI Hose is offered a more stable vacuum state by a continuous pumping of vacuum pump system on site, and the rest of the assembly and process treatment is still in the manufacturing factory.
Dynamic Vacuum Insulated Flexible Hose | Static Vacuum Insulated Flexible Hose | |
Introduction | The vacuum degree of the vacuum interlayer is monitored continuously, and the vacuum pump is automatically controlled to open and close, to ensure the stability and effectiveness of vacuum degree | VJ Flexible Hoses complete the vacuum insulation work in the manufacturing plant. |
Advantages | The vacuum retention is more stable, basically eliminate the vacuum maintenance in the future working. | More economical investment and simple on-site installation |
Vacuum Bayonet Connection Type with Clamps |
Applicative |
Applicative |
Vacuum Bayonet Connection Type with Flanges and Bolts |
Applicative |
Applicative |
Welded Connection Type |
Applicative |
Applicative |
Thread Joint Connection Type |
Applicative |
Applicative |
Dynamic Vacuum Insulated Flexible Hose System: Consist of Vacuum Flexible Hoses, Jumper Hoses and Vacuum Pump System (including the vacuum pumps, solenoid valves and vacuum gauges). Easily installed in small room. The length of single Vacuum Insulated Flexible Hose can be customized according to customer’s requirements.
2.SPECIFICATION AND MODEL
HL-HX-X-000-00-X
Brand
HL Cryogenic Equipment
Description
HD: Dynamic VI Hose
HS: Static VI Hose
Connection Type
W: Welded Connection Type
B: Vacuum Bayonet Connection Type with Clamps
F: Vacuum Bayonet Connection Type with Flanges and bolts
T:Thread Joint Connection Type
Nominal Diameter of Inner Pipe
010: DN10
…
080: DN80
…
150: DN150
Design Pressure
08: 8bar
16: 16bar
25: 25bar
32: 32bar
40: 40bar
Material of Inner Pipe
A: SS304
B: SS304L
C: SS316
D: SS316L
E: Other
3.1 Static Vacuum Insulated Cryogenic Flexible Hose
Model |
Connection Type |
Nominal Diameter of Inner Pipe |
Design Pressure |
Material of Inner Pipe |
Standard |
Remark |
HLHSB01008X |
Vacuum Bayonet Connection Type with Clamps for Static Vacuum Insulated Flexible Hose |
DN10, 3/8" |
8 bar
|
300 Series Stainless Steel |
ASME B31.3 |
X:
Material of Inner Pipe. A is 304, B is 304L, C is 316, D is 316L, E is other. |
HLHSB01508X |
DN15, 1/2" |
|||||
HLHSB02008X |
DN20, 3/4" |
|||||
HLHSB02508X |
DN25, 1" |
Nominal Diameter of Inner Pipe: Recommended ≤ DN25 or 1". Or selects the Vacuum Bayonet Connection Type with Flanges and Bolts (from DN10, 3/8" to DN80, 3"), Welded Connection Type (from DN10, 3/8" to DN150, 6")
Nominal Diameter of Outer Pipe: Recommended by the Enterprise Standard of HL Cryogenic Equipment. It also can be produced according to requirement of the customer.
Design Pressure: Recommended ≤ 8 bar. Or selects the Vacuum Bayonet Connection Type with Flanges and Bolts (≤16 bar), Welded Connection Type (≤40 bar)
Material of Outer Pipe: Without special requirement, the material of inner pipe and outer pipe will be selected the same.
Model |
Connection Type |
Nominal Diameter of Inner Pipe |
Design Pressure |
Material of Inner Pipe |
Standard |
Remark |
HLHSF01000X |
Vacuum Bayonet Connection Type with Flanges and Bolts for Static Vacuum Insulated Flexible Hose |
DN10, 3/8" |
8~16 bar |
300 Series Stainless Steel |
ASME B31.3 |
00:
Design Pressure. 08 is 8bar, 16 is 16bar.
X: Material of Inner Pipe. A is 304, B is 304L, C is 316, D is 316L, E is other. |
HLHSF01500X |
DN15, 1/2" |
|||||
HLHSF02000X |
DN20, 3/4" |
|||||
HLHSF02500X |
DN25, 1" |
|||||
HLHSF03200X |
DN32, 1-1/4" |
|||||
HLHSF04000X |
DN40, 1-1/2" |
|||||
HLHSF05000X |
DN50, 2" |
|||||
HLHSF06500X |
DN65, 2-1/2" |
|||||
HLHSF08000X |
DN80, 3" |
Nominal Diameter of Inner Pipe: Recommended ≤ DN80 or 3". Or selects the Welded Connection Type (from DN10, 3/8" to DN150, 6"), Vacuum Bayonet Connection Type with Clamps (from DN10, 3/8" to DN25, 1").
Nominal Diameter of Outer Pipe: Recommended by the Enterprise Standard of HL Cryogenic Equipment. It also can be produced according to requirement of the customer.
Design Pressure: Recommended ≤ 16 bar. Or selects Welded Connection Type (≤40 bar).
Material of Outer Pipe: Without special requirement, the material of inner pipe and outer pipe will be selected the same.
Model |
Connection Type |
Nominal Diameter of Inner Pipe |
Design Pressure |
Material of Inner Pipe |
Standard |
Remark |
HLHSW01000X |
Welded Connection Type for Static Vacuum Insulated Flexible Hose |
DN10, 3/8" |
8~40 bar |
300 Series Stainless Steel |
ASME B31.3 |
00:
Design Pressure 08 is 8bar, 16 is 16bar, and 25, 32, 40.
X: Material of Inner Pipe. A is 304, B is 304L, C is 316, D is 316L, E is other. |
HLHSW01500X |
DN15, 1/2" |
|||||
HLHSW02000X |
DN20, 3/4" |
|||||
HLHSW02500X |
DN25, 1" |
|||||
HLHSW03200X |
DN32, 1-1/4" |
|||||
HLHSW04000X |
DN40, 1-1/2" |
|||||
HLHSW05000X |
DN50, 2" |
|||||
HLHSW06500X |
DN65, 2-1/2" |
|||||
HLHSW08000X |
DN80, 3" |
|||||
HLHSW10000X |
DN100, 4" |
|||||
HLHSW12500X |
DN125, 5" |
|||||
HLHSW15000X |
DN150, 6" |
Nominal Diameter of Outer Pipe: Recommended by the Enterprise Standard of HL Cryogenic Equipment. It also can be produced according to requirement of the customer.
Material of Outer Pipe: Without special requirement, the material of inner pipe and outer pipe will be selected the same.
Model |
Connection Type |
Nominal Diameter of Inner Pipe |
Design Pressure |
Material of Inner Pipe |
Standard |
Remark |
HLHST01000X |
Vacuum Bayonet Connection Type with Clamps for Static Vacuum Insulated Flexible Hose |
DN10, 3/8" |
8~16 bar |
300 Series Stainless Steel |
ASME B31.3 |
00:
Design Pressure. 08 is 8bar, 16 is 16bar.
X: Material of Inner Pipe. A is 304, B is 304L, C is 316, D is 316L, E is other. |
HLHSB01500X |
DN15, 1/2" |
|||||
HLHSB02000X |
DN20, 3/4" |
|||||
HLHSB02500X |
DN25, 1" |
Nominal Diameter of Inner Pipe: Recommended ≤ DN25 or 1". Or selects the Vacuum Bayonet Connection Type with Flanges and Bolts (from DN10, 3/8" to DN80, 3"), Welded Connection Type (from DN10, 3/8" to DN150, 6")
Nominal Diameter of Outer Pipe: Recommended by the Enterprise Standard of HL Cryogenic Equipment. It also can be produced according to requirement of the customer.
Design Pressure: Recommended ≤ 16 bar. Or selects the Welded Connection Type (≤40 bar)
Material of Outer Pipe: Without special requirement, the material of inner pipe and outer pipe will be selected the same.
3.2Dynamic Vacuum Insulated Piping System
Model |
Connection Type |
Nominal Diameter of Inner Pipe |
Design Pressure |
Material of Inner Pipe |
Standard |
Remark |
HLHDB01008X |
Vacuum Bayonet Connection Type with Clamps for Dynamic Vacuum Insulated Flexible Hose |
DN10, 3/8" |
8 bar
|
300 Series Stainless Steel |
ASME B31.3 |
X:Material of Inner Pipe.
A is 304, B is 304L, C is 316, D is 316L, E is other. |
HLHDB01508X |
DN15, 1/2" |
|||||
HLHDB02008X |
DN20, 3/4" |
|||||
HLHDB02508X |
DN25, 1" |
Nominal Diameter of Inner Pipe: Recommended ≤ DN25 or 1". Or selects the Vacuum Bayonet Connection Type with Flanges and Bolts (from DN10, 3/8" to DN80, 3"), Welded Connection Type (from DN10, 3/8" to DN150, 6")
Nominal Diameter of Outer Pipe: Recommended by the Enterprise Standard of HL Cryogenic Equipment. It also can be produced according to requirement of the customer.
Design Pressure: Recommended ≤ 8 bar. Or selects the Vacuum Bayonet Connection Type with Flanges and Bolts (≤16 bar), Welded Connection Type (≤40 bar)
Material of Outer Pipe: Without special requirement, the material of inner pipe and outer pipe will be selected the same.
Power Condition: The site needs to supply power to the vacuum pumps and inform HL Cryogenic Equipment the local electricity information (Voltage and Hertz).
Model |
Connection Type |
Nominal Diameter of Inner Pipe |
Design Pressure |
Material of Inner Pipe |
Standard |
Remark |
HLHDF01000X |
Vacuum Bayonet Connection Type with Flanges and Bolts for Dynamic Vacuum Insulated Flexible Hose |
DN10, 3/8" |
8~16 bar |
300 Series Stainless Steel |
ASME B31.3 |
00: Design Pressure.
08 is 8bar, 16 is 16bar.
X: Material of Inner Pipe. A is 304, B is 304L, C is 316, D is 316L, E is other. |
HLHDF01500X |
DN15, 1/2" |
|||||
HLHDF02000X |
DN20, 3/4" |
|||||
HLHDF02500X |
DN25, 1" |
|||||
HLHDF03200X |
DN32, 1-1/4" |
|||||
HLHDF04000X |
DN40, 1-1/2" |
|||||
HLHDF05000X |
DN50, 2" |
|||||
HLHDF06500X |
DN65, 2-1/2" |
|||||
HLHDF08000X |
DN80, 3" |
Nominal Diameter of Inner Pipe: Recommended ≤ DN80 or 3". Or selects the Welded Connection Type (from DN10, 3/8" to DN150, 6"), Vacuum Bayonet Connection Type with Clamps (from DN10, 3/8" to DN25, 1").
Nominal Diameter of Outer Pipe: Recommended by the Enterprise Standard of HL Cryogenic Equipment. It also can be produced according to requirement of the customer.
Design Pressure: Recommended ≤ 16 bar. Or selects Welded Connection Type (≤40 bar).
Material of Outer Pipe: Without special requirement, the material of inner pipe and outer pipe will be selected the same.
Power Condition: The site needs to supply power to the vacuum pumps and inform HL Cryogenic Equipment the local electricity information (Voltage and Hertz).
Model |
Connection Type |
Nominal Diameter of Inner Pipe |
Design Pressure |
Material of Inner Pipe |
Standard |
Remark |
HLHDW01000X |
Welded Connection Type for Dynamic Vacuum Insulated Flexible Hose |
DN10, 3/8" |
8~40 bar |
Stainless Steel 304, 304L, 316, 316L |
ASME B31.3 |
00:
Design Pressure 08 is 8bar, 16 is 16bar, and 25, 32, 40. .
X: Material of Inner Pipe. A is 304, B is 304L, C is 316, D is 316L, E is other. |
HLHDW01500X |
DN15, 1/2" |
|||||
HLHDW02000X |
DN20, 3/4" |
|||||
HLHDW02500X |
DN25, 1" |
|||||
HLHDW03200X |
DN32, 1-1/4" |
|||||
HLHDW04000X |
DN40, 1-1/2" |
|||||
HLHDW05000X |
DN50, 2" |
|||||
HLHDW06500X |
DN65, 2-1/2" |
|||||
HLHDW08000X |
DN80, 3" |
|||||
HLHDW10000X |
DN100, 4" |
|||||
HLHDW12500X |
DN125, 5" |
|||||
HLHDW15000X |
DN150, 6" |
Nominal Diameter of Outer Pipe: Recommended by the Enterprise Standard of HL Cryogenic Equipment. It also can be produced according to requirement of the customer.
Material of Outer Pipe: Without special requirement, the material of inner pipe and outer pipe will be selected the same.
Power Condition: The site needs to supply power to the vacuum pumps and inform HL Cryogenic Equipment the local electricity information (Voltage and Hertz).
Model |
Connection Type |
Nominal Diameter of Inner Pipe |
Design Pressure |
Material of Inner Pipe |
Standard |
Remark |
HLHDT01000X |
Vacuum Bayonet Connection Type with Clamps for Dynamic Vacuum Insulated Flexible Hose |
DN10, 3/8" |
8~16 bar |
300 Series Stainless Steel |
ASME B31.3 |
00:
Design Pressure. 08 is 8bar, 16 is 16bar.
X: Material of Inner Pipe. A is 304, B is 304L, C is 316, D is 316L, E is other. |
HLHDB01500X |
DN15, 1/2" |
|||||
HLHDB02000X |
DN20, 3/4" |
|||||
HLHDB02500X |
DN25, 1" |
Nominal Diameter of Inner Pipe: Recommended ≤ DN25 or 1". Or selects the Vacuum Bayonet Connection Type with Flanges and Bolts (from DN10, 3/8" to DN80, 3"), Welded Connection Type (from DN10, 3/8" to DN150, 6")
Nominal Diameter of Outer Pipe: Recommended by the Enterprise Standard of HL Cryogenic Equipment. It also can be produced according to requirement of the customer.
Design Pressure: Recommended ≤ 16 bar. Or selects the, Welded Connection Type (≤40 bar)
Material of Outer Pipe: Without special requirement, the material of inner pipe and outer pipe will be selected the same.
Power Condition: The site needs to supply power to the vacuum pumps and inform HL Cryogenic Equipment the local electricity information (Voltage and Hertz).