Vacuum Insulated Flexible Hose Series Pricelist
Introduction: As a leading manufacturing factory, we are proud to introduce our Vacuum Insulated Flexible Hose Series. In this article, we will provide an overview of this revolutionary product, highlighting its key selling points and competitive advantages. From its exceptional insulation capabilities to its unmatched flexibility, our Vacuum Insulated Flexible Hose Series offers efficient solutions for various industrial applications. Read on to explore the details of this groundbreaking product.
Product Highlights:
- Superior Insulation: Our Vacuum Insulated Flexible Hose Series utilizes advanced insulation technology to minimize heat transfer effectively. The vacuum-insulated design ensures optimal thermal performance, enhancing energy efficiency and reducing heat losses. This leads to substantial cost savings and improved operational performance for our customers.
- Flexibility: Designed with flexibility in mind, our Vacuum Insulated Flexible Hose Series allows for easy installation and maneuverability. The flexible construction enables the hose to adapt to different angles and spaces, making it suitable for complex industrial settings. This flexibility ensures that the hose can be easily integrated into existing systems, saving time and effort during installation.
- Versatile Applications: Our Vacuum Insulated Flexible Hose Series is engineered to meet the demands of various industries, including:
- Heating, ventilation, and air conditioning (HVAC) systems
- Chemical and petrochemical processes
- Cryogenic applications
- Food processing
- Pharmaceutical manufacturing
With its versatility, our Vacuum Insulated Flexible Hose Series serves as a reliable solution in different industrial sectors, providing efficient insulation and maintaining optimal temperature conditions.
- Customizable Options: We offer a range of customization options for our Vacuum Insulated Flexible Hose Series, including different lengths, sizes, and end fittings. This enables our customers to select the most suitable configurations for their specific requirements. Our team of experts is available to guide customers through the customization process, ensuring that they receive a tailored solution to meet their needs precisely.
Product Details:
- Construction:
- Inner Tube: Transports the fluid or substance
- Insulation Layer: Minimizes heat transfer and enhances thermal performance
- Outer Jacket: Provides protection and durability
- Features:
- Advanced insulation technology for maximum heat retention
- Flexible design for easy installation and maneuverability
- Customization options to meet specific requirements
- High-quality construction for long-term durability
- Compliance with industry standards and regulations
Conclusion: Experience the remarkable insulation capabilities and flexibility offered by our Vacuum Insulated Flexible Hose Series. With its advanced insulation technology, customizable options, and unmatched versatility, our product provides efficient solutions for various industrial applications. Contact us today to request our up-to-date pricelist and discover how our Vacuum Insulated Flexible Hose Series can enhance your operations.
Word Count: XXX words (including title and conclusion)
Video
Vacuum Insulated Piping
Vacuum Insulated Hose (vacuum hose), namely Vacuum Jacketed Hose, as a Perfect substitute for conventional piping insulation. Compared with conventional piping insulation, the heat leakage value of VIP is only 0.05~0.035 times of conventional piping insulation. Significantly save energy and cost for customers.
The product series of Vacuum Insulated Hose, Vacuum Insulated Pipe, Vacuum Insulated Valve, and Phase Separator in HL Cryogenic Equipment Company, which passed through a series of extremely strict technical treatments, are used for transferring of liquid oxygen, liquid nitrogen, liquid argon, liquid hydrogen, liquid helium, LEG and LNG, and these products are serviced for cryogenic equipment (e.g. cryogenic tank, dewar and coldbox etc.) in industries of air separation, gases, aviation, electronics, superconductor, chips, pharmacy, hospital, biobank, food & beverage, automation assembly, rubber, new material manufacturing chemical engineering, iron & steel, and scientific research etc.
Four Connection Types
In order to maximize the different needs of customers, there are usually four connection types for VI Flexible Hose. The first three connection types apply only to the connection positions between VI Flexible Hoses. The fourth one, threaded connection type is generally used only for VI Hose connections to equipment and storage tank.
When VI Flexible Hose connects with equipment, storage tank and so on, the connection joint can be customized according to customer requirements.
Scope of Application
Vacuum Bayonet Connection Type with Clamps |
Vacuum Bayonet Connection Type with Flanges and Bolts |
Welded Connection Type |
Thread Joint Connection Type |
|
Connection Type |
Clamps |
Flanges and Bolts |
Weld |
Thread |
Insulation Type at joints |
Vacuum |
Vacuum |
Perlite or Vacuum |
Wrapping Insulated Materials |
On-site Insulated Treatment |
No |
No |
Yes, perlite filled into or vacuum pump out from the Insulated Sleeves at joints. |
Yes |
Nominal Diameter of Inner Pipe |
DN10(3/8")~DN25(1") |
DN10(3/8")~DN80(3") |
DN10(3/8")~DN150(6") |
DN10(3/8")~DN25(1") |
Design Pressure |
≤8 bar |
≤16 bar |
≤40 bar |
≤16 bar |
Installation |
Easy |
Easy |
Weld |
Easy |
Design Temperature |
-196℃~ 90℃ (LH2 & LHe:-270℃ ~ 90℃) |
|||
Length |
≥ 1 meter/pcs |
|||
Material |
300 Series Stainless Steel |
|||
Medium |
LN2, LOX, LAr, LHe, LH2, LNG |
Protective Cover
Product Scope of Supply
Product |
Specification |
Vacuum Bayonet Connection with Clamps |
Vacuum Bayonet Connection with Flanges and Bolts |
Weld Insulated Connection |
Thread Connection |
Vacuum Insulated Flexible Hose |
DN8 |
YES |
YES |
YES |
YES |
DN15 |
YES |
YES |
YES |
YES |
|
DN20 |
YES |
YES |
YES |
YES |
|
DN25 |
YES |
YES |
YES |
YES |
|
DN32 |
/ |
YES |
YES |
/ |
|
DN40 |
/ |
YES |
YES |
/ |
|
DN50 |
/ |
YES |
YES |
/ |
|
DN65 |
/ |
YES |
YES |
/ |
|
DN80 |
/ |
YES |
YES |
/ |
|
DN100 |
/ |
/ |
YES |
/ |
|
DN125 |
/ |
/ |
YES |
/ |
|
DN150 |
/ |
/ |
YES |
/ |
Technical Characteristic
Design Temperature | -196~90℃ (LHe:-270~90℃) |
Ambient Temperature | -50~90℃ |
Vacuum Leakage Rate | ≤1*10-10Pa*m3/S |
Vacuum Level after Guarantee | ≤0.1 Pa |
Insulated Method | High Vacuum Multi-Layer Insulation. |
Adsorbent and Getter | Yes |
Test Pressure | 1.15 Times Design Pressure |
Medium | LO2、LN2、LAr、LH2、LHe、LEG、LNG |
Dynamic and Static Vacuum Insulated Flexible Hose
Vacuum Insulated (VI) Flexible Hose can be divided into Dynamic and Static VI Flexible Hose.
l The Static VI Hose is fully completed in the manufacturing factory.
l The Dynamic VI System is offered a more stable vacuum state by a continuous pumping of vacuum pump system on site, and vacuuming treatment will no longer take place in the factory. The rest of the assembly and process treatment is still in the manufacturing factory. So, the Dynamic VJ Piping needs to be equipped with a Vacuum Pump System.
Dynamic Vacuum Insulated Flexible Hose | Static Vacuum Insulated Flexible Hose | |
Introduction | The vacuum degree of the vacuum interlayer is monitored continuously, and the vacuum pump is automatically controlled to open and close, to ensure the stability and effectiveness of vacuum degree | VJ Flexible Hoses complete the vacuum insulation work in the manufacturing plant. |
Advantages | The vacuum retention is more stable, basically eliminate the vacuum maintenance in the future working. | More economical investment and simple on-site installation |
Vacuum Bayonet Connection Type with Clamps |
Applicative |
Applicative |
Vacuum Bayonet Connection Type with Flanges and Bolts |
Applicative |
Applicative |
Welded Connection Type |
Applicative |
Applicative |
Thread Joint Connection Type |
Applicative |
Applicative |
Dynamic Vacuum Insulated Flexible Hose System: Consist of Vacuum Flexible Hoses, Jumper Hoses and Vacuum Pump System (including the vacuum pumps, solenoid valves and vacuum gauges). Easily installed in small room. The length of single Vacuum Insulated Flexible Hose can be customized according to customer’s requirements.
2.SPECIFICATION AND MODEL
HL-HX-X-000-00-X
Brand
HL Cryogenic Equipment
Description
HD: Dynamic VI Hose
HS: Static VI Hose
Connection Type
W: Welded Connection Type
B: Vacuum Bayonet Connection Type with Clamps
F: Vacuum Bayonet Connection Type with Flanges and bolts
T:Thread Joint Connection Type
Nominal Diameter of Inner Pipe
010: DN10
…
080: DN80
…
150: DN150
Design Pressure
08: 8bar
16: 16bar
25: 25bar
32: 32bar
40: 40bar
Material of Inner Pipe
A: SS304
B: SS304L
C: SS316
D: SS316L
E: Other
3.1 Static Vacuum Insulated Cryogenic Flexible Hose
Model |
Connection Type |
Nominal Diameter of Inner Pipe |
Design Pressure |
Material of Inner Pipe |
Standard |
Remark |
HLHSB01008X |
Vacuum Bayonet Connection Type with Clamps for Static Vacuum Insulated Flexible Hose |
DN10, 3/8" |
8 bar
|
300 Series Stainless Steel |
ASME B31.3 |
X:
Material of Inner Pipe. A is 304, B is 304L, C is 316, D is 316L, E is other. |
HLHSB01508X |
DN15, 1/2" |
|||||
HLHSB02008X |
DN20, 3/4" |
|||||
HLHSB02508X |
DN25, 1" |
Nominal Diameter of Inner Pipe: Recommended ≤ DN25 or 1". Or selects the Vacuum Bayonet Connection Type with Flanges and Bolts (from DN10, 3/8" to DN80, 3"), Welded Connection Type (from DN10, 3/8" to DN150, 6")
Nominal Diameter of Outer Pipe: Recommended by the Enterprise Standard of HL Cryogenic Equipment. It also can be produced according to requirement of the customer.
Design Pressure: Recommended ≤ 8 bar. Or selects the Vacuum Bayonet Connection Type with Flanges and Bolts (≤16 bar), Welded Connection Type (≤40 bar)
Material of Outer Pipe: Without special requirement, the material of inner pipe and outer pipe will be selected the same.
Model |
Connection Type |
Nominal Diameter of Inner Pipe |
Design Pressure |
Material of Inner Pipe |
Standard |
Remark |
HLHSF01000X |
Vacuum Bayonet Connection Type with Flanges and Bolts for Static Vacuum Insulated Flexible Hose |
DN10, 3/8" |
8~16 bar |
300 Series Stainless Steel |
ASME B31.3 |
00:
Design Pressure. 08 is 8bar, 16 is 16bar.
X: Material of Inner Pipe. A is 304, B is 304L, C is 316, D is 316L, E is other. |
HLHSF01500X |
DN15, 1/2" |
|||||
HLHSF02000X |
DN20, 3/4" |
|||||
HLHSF02500X |
DN25, 1" |
|||||
HLHSF03200X |
DN32, 1-1/4" |
|||||
HLHSF04000X |
DN40, 1-1/2" |
|||||
HLHSF05000X |
DN50, 2" |
|||||
HLHSF06500X |
DN65, 2-1/2" |
|||||
HLHSF08000X |
DN80, 3" |
Nominal Diameter of Inner Pipe: Recommended ≤ DN80 or 3". Or selects the Welded Connection Type (from DN10, 3/8" to DN150, 6"), Vacuum Bayonet Connection Type with Clamps (from DN10, 3/8" to DN25, 1").
Nominal Diameter of Outer Pipe: Recommended by the Enterprise Standard of HL Cryogenic Equipment. It also can be produced according to requirement of the customer.
Design Pressure: Recommended ≤ 16 bar. Or selects Welded Connection Type (≤40 bar).
Material of Outer Pipe: Without special requirement, the material of inner pipe and outer pipe will be selected the same.
Model |
Connection Type |
Nominal Diameter of Inner Pipe |
Design Pressure |
Material of Inner Pipe |
Standard |
Remark |
HLHSW01000X |
Welded Connection Type for Static Vacuum Insulated Flexible Hose |
DN10, 3/8" |
8~40 bar |
300 Series Stainless Steel |
ASME B31.3 |
00:
Design Pressure 08 is 8bar, 16 is 16bar, and 25, 32, 40.
X: Material of Inner Pipe. A is 304, B is 304L, C is 316, D is 316L, E is other. |
HLHSW01500X |
DN15, 1/2" |
|||||
HLHSW02000X |
DN20, 3/4" |
|||||
HLHSW02500X |
DN25, 1" |
|||||
HLHSW03200X |
DN32, 1-1/4" |
|||||
HLHSW04000X |
DN40, 1-1/2" |
|||||
HLHSW05000X |
DN50, 2" |
|||||
HLHSW06500X |
DN65, 2-1/2" |
|||||
HLHSW08000X |
DN80, 3" |
|||||
HLHSW10000X |
DN100, 4" |
|||||
HLHSW12500X |
DN125, 5" |
|||||
HLHSW15000X |
DN150, 6" |
Nominal Diameter of Outer Pipe: Recommended by the Enterprise Standard of HL Cryogenic Equipment. It also can be produced according to requirement of the customer.
Material of Outer Pipe: Without special requirement, the material of inner pipe and outer pipe will be selected the same.
Model |
Connection Type |
Nominal Diameter of Inner Pipe |
Design Pressure |
Material of Inner Pipe |
Standard |
Remark |
HLHST01000X |
Vacuum Bayonet Connection Type with Clamps for Static Vacuum Insulated Flexible Hose |
DN10, 3/8" |
8~16 bar |
300 Series Stainless Steel |
ASME B31.3 |
00:
Design Pressure. 08 is 8bar, 16 is 16bar.
X: Material of Inner Pipe. A is 304, B is 304L, C is 316, D is 316L, E is other. |
HLHSB01500X |
DN15, 1/2" |
|||||
HLHSB02000X |
DN20, 3/4" |
|||||
HLHSB02500X |
DN25, 1" |
Nominal Diameter of Inner Pipe: Recommended ≤ DN25 or 1". Or selects the Vacuum Bayonet Connection Type with Flanges and Bolts (from DN10, 3/8" to DN80, 3"), Welded Connection Type (from DN10, 3/8" to DN150, 6")
Nominal Diameter of Outer Pipe: Recommended by the Enterprise Standard of HL Cryogenic Equipment. It also can be produced according to requirement of the customer.
Design Pressure: Recommended ≤ 16 bar. Or selects the Welded Connection Type (≤40 bar)
Material of Outer Pipe: Without special requirement, the material of inner pipe and outer pipe will be selected the same.
3.2Dynamic Vacuum Insulated Piping System
Model |
Connection Type |
Nominal Diameter of Inner Pipe |
Design Pressure |
Material of Inner Pipe |
Standard |
Remark |
HLHDB01008X |
Vacuum Bayonet Connection Type with Clamps for Dynamic Vacuum Insulated Flexible Hose |
DN10, 3/8" |
8 bar
|
300 Series Stainless Steel |
ASME B31.3 |
X:Material of Inner Pipe.
A is 304, B is 304L, C is 316, D is 316L, E is other. |
HLHDB01508X |
DN15, 1/2" |
|||||
HLHDB02008X |
DN20, 3/4" |
|||||
HLHDB02508X |
DN25, 1" |
Nominal Diameter of Inner Pipe: Recommended ≤ DN25 or 1". Or selects the Vacuum Bayonet Connection Type with Flanges and Bolts (from DN10, 3/8" to DN80, 3"), Welded Connection Type (from DN10, 3/8" to DN150, 6")
Nominal Diameter of Outer Pipe: Recommended by the Enterprise Standard of HL Cryogenic Equipment. It also can be produced according to requirement of the customer.
Design Pressure: Recommended ≤ 8 bar. Or selects the Vacuum Bayonet Connection Type with Flanges and Bolts (≤16 bar), Welded Connection Type (≤40 bar)
Material of Outer Pipe: Without special requirement, the material of inner pipe and outer pipe will be selected the same.
Power Condition: The site needs to supply power to the vacuum pumps and inform HL Cryogenic Equipment the local electricity information (Voltage and Hertz).
Model |
Connection Type |
Nominal Diameter of Inner Pipe |
Design Pressure |
Material of Inner Pipe |
Standard |
Remark |
HLHDF01000X |
Vacuum Bayonet Connection Type with Flanges and Bolts for Dynamic Vacuum Insulated Flexible Hose |
DN10, 3/8" |
8~16 bar |
300 Series Stainless Steel |
ASME B31.3 |
00: Design Pressure.
08 is 8bar, 16 is 16bar.
X: Material of Inner Pipe. A is 304, B is 304L, C is 316, D is 316L, E is other. |
HLHDF01500X |
DN15, 1/2" |
|||||
HLHDF02000X |
DN20, 3/4" |
|||||
HLHDF02500X |
DN25, 1" |
|||||
HLHDF03200X |
DN32, 1-1/4" |
|||||
HLHDF04000X |
DN40, 1-1/2" |
|||||
HLHDF05000X |
DN50, 2" |
|||||
HLHDF06500X |
DN65, 2-1/2" |
|||||
HLHDF08000X |
DN80, 3" |
Nominal Diameter of Inner Pipe: Recommended ≤ DN80 or 3". Or selects the Welded Connection Type (from DN10, 3/8" to DN150, 6"), Vacuum Bayonet Connection Type with Clamps (from DN10, 3/8" to DN25, 1").
Nominal Diameter of Outer Pipe: Recommended by the Enterprise Standard of HL Cryogenic Equipment. It also can be produced according to requirement of the customer.
Design Pressure: Recommended ≤ 16 bar. Or selects Welded Connection Type (≤40 bar).
Material of Outer Pipe: Without special requirement, the material of inner pipe and outer pipe will be selected the same.
Power Condition: The site needs to supply power to the vacuum pumps and inform HL Cryogenic Equipment the local electricity information (Voltage and Hertz).
Model |
Connection Type |
Nominal Diameter of Inner Pipe |
Design Pressure |
Material of Inner Pipe |
Standard |
Remark |
HLHDW01000X |
Welded Connection Type for Dynamic Vacuum Insulated Flexible Hose |
DN10, 3/8" |
8~40 bar |
Stainless Steel 304, 304L, 316, 316L |
ASME B31.3 |
00:
Design Pressure 08 is 8bar, 16 is 16bar, and 25, 32, 40. .
X: Material of Inner Pipe. A is 304, B is 304L, C is 316, D is 316L, E is other. |
HLHDW01500X |
DN15, 1/2" |
|||||
HLHDW02000X |
DN20, 3/4" |
|||||
HLHDW02500X |
DN25, 1" |
|||||
HLHDW03200X |
DN32, 1-1/4" |
|||||
HLHDW04000X |
DN40, 1-1/2" |
|||||
HLHDW05000X |
DN50, 2" |
|||||
HLHDW06500X |
DN65, 2-1/2" |
|||||
HLHDW08000X |
DN80, 3" |
|||||
HLHDW10000X |
DN100, 4" |
|||||
HLHDW12500X |
DN125, 5" |
|||||
HLHDW15000X |
DN150, 6" |
Nominal Diameter of Outer Pipe: Recommended by the Enterprise Standard of HL Cryogenic Equipment. It also can be produced according to requirement of the customer.
Material of Outer Pipe: Without special requirement, the material of inner pipe and outer pipe will be selected the same.
Power Condition: The site needs to supply power to the vacuum pumps and inform HL Cryogenic Equipment the local electricity information (Voltage and Hertz).
Model |
Connection Type |
Nominal Diameter of Inner Pipe |
Design Pressure |
Material of Inner Pipe |
Standard |
Remark |
HLHDT01000X |
Vacuum Bayonet Connection Type with Clamps for Dynamic Vacuum Insulated Flexible Hose |
DN10, 3/8" |
8~16 bar |
300 Series Stainless Steel |
ASME B31.3 |
00:
Design Pressure. 08 is 8bar, 16 is 16bar.
X: Material of Inner Pipe. A is 304, B is 304L, C is 316, D is 316L, E is other. |
HLHDB01500X |
DN15, 1/2" |
|||||
HLHDB02000X |
DN20, 3/4" |
|||||
HLHDB02500X |
DN25, 1" |
Nominal Diameter of Inner Pipe: Recommended ≤ DN25 or 1". Or selects the Vacuum Bayonet Connection Type with Flanges and Bolts (from DN10, 3/8" to DN80, 3"), Welded Connection Type (from DN10, 3/8" to DN150, 6")
Nominal Diameter of Outer Pipe: Recommended by the Enterprise Standard of HL Cryogenic Equipment. It also can be produced according to requirement of the customer.
Design Pressure: Recommended ≤ 16 bar. Or selects the, Welded Connection Type (≤40 bar)
Material of Outer Pipe: Without special requirement, the material of inner pipe and outer pipe will be selected the same.
Power Condition: The site needs to supply power to the vacuum pumps and inform HL Cryogenic Equipment the local electricity information (Voltage and Hertz).