Vacuum Insulated Pipe Series
Product Brief:
- LN2 Pipe Series: A comprehensive range of high-quality pipes designed for efficient liquid nitrogen transportation.
- Superior durability, reliable performance, and precise control ensure safe and efficient LN2 handling.
- Manufactured by our leading production factory, delivering trusted quality and excellent customer service.
Product Description:
I. Superior Durability and Reliability:
- The LN2 Pipe Series is built to withstand extreme temperatures and harsh working conditions, ensuring unmatched durability and reliability.
- Constructed with high-quality materials, these pipes offer long-lasting performance and minimal maintenance requirements.
II. Efficient Liquid Nitrogen Transportation:
- These pipes are specifically designed to facilitate the efficient transportation of liquid nitrogen from one point to another.
- With their smooth interior surface and optimized flow dynamics, they minimize pressure drop and ensure maximum LN2 flow, enhancing overall efficiency.
III. Precise Control and Safety:
- Designed with precision in mind, the LN2 Pipe Series allows for accurate control over the LN2 flow, ensuring optimal safety during transportation.
- Their tight sealing capabilities prevent any leakage or loss of LN2, minimizing wastage and improving cost-effectiveness.
IV. Customizable Solutions:
- Our LN2 Pipe Series offers a range of sizes and configurations to meet the specific requirements of different applications.
- Customization options include lengths, diameters, and material choices, allowing for seamless integration into existing systems.
V. Industry-leading Manufacturing:
- Produced in our state-of-the-art production facility, the LN2 Pipe Series undergoes stringent quality control measures, guaranteeing exceptional performance and longevity.
- Our factory is equipped with advanced machinery and staffed by skilled engineers and technicians, ensuring consistent quality and prompt delivery.
In conclusion, the LN2 Pipe Series provides the optimal solution for efficient liquid nitrogen transportation. With its superior durability, precise control, and industry-leading manufacturing, it ensures safe and reliable LN2 handling in diverse industrial applications. Choose our LN2 Pipe Series for trusted quality, efficient performance, and excellent customer satisfaction.
Video
Vacuum Insulated Piping
Vacuum Insulated Pipe (VI Piping), namely Vacuum Jacketed Pipe (VJ Piping), as a Perfect substitute for conventional piping insulation. Compared with conventional piping insulation, the heat leakage value of VIP is only 0.05~0.035 times of conventional piping insulation. Significantly save energy and cost for customers.
The product series of Vacuum Jacketed Pipe, Vacuum Jacketed Hose, Vacuum Jacketed Valve, and Phase Separator in HL Cryogenic Equipment Company, which passed through a series of extremely strict technical treatments, are used for transferring of liquid oxygen, liquid nitrogen, liquid argon, liquid hydrogen, liquid helium, LEG and LNG, and these products are serviced for cryogenic equipment (e.g. cryogenic tanks, dewars and coldboxes etc.) in industries of air separation, gases, aviation, electronics, superconductor, chips, automation assembly, food & beverage, pharmacy, hospital, biobank, rubber, new material manufacturing chemical engineering, iron & steel, and scientific research etc.
Three Connection Types of VI Piping
The three connection types here apply only to the connection positions between VI pipes. When VI Pipe connects with equipment, storage tank and so on, the connection joint can be customized according to customer requirements.
In order to maximize the different needs of customers, Vacuum Insulated Pipe has developed three connection types, namely Vacuum Bayonet Connection Type with Clamps, Vacuum Bayonet Connection Type with Flanges and Bolts and Welded Connection Type. They have different advantages and are suitable for different working conditions.
Scope of Application
Vacuum Bayonet Connection Type with Clamps |
Vacuum Bayonet Connection Type with Flanges and Bolts |
Welded Connection Type |
|
Connection Type |
Clamps |
Flanges and Bolts |
Weld |
Insulation Type at joints |
Vacuum |
Vacuum |
Perlite or Vacuum |
On-site Insulated Treatment |
No |
No |
Yes, perlite filled into or vacuum pump out from the Insulated Sleeves at joints. |
Nominal Diameter of Inner Pipe |
DN10(3/8")~DN25(1") |
DN10(3/8")~DN80(3") |
DN10(3/8")~DN500(20") |
Design Pressure |
≤8 bar |
≤16 bar |
≤64 bar |
Installation |
Easy |
Easy |
Weld |
Design Temperature |
-196℃~ 90℃ (LH2 & LHe:-270℃ ~ 90℃) |
||
Length |
1 ~ 8.2 meter/pcs |
||
Material |
300 Series Stainless Steel |
||
Medium |
LN2, LOX, LAr, LHe, LH2, LEG, LNG |
Product Scope of Supply
Product |
Specification |
Vacuum Bayonet Connection with Clamps |
Vacuum Bayonet Connection with Flanges and Bolts |
Weld Insulated Connection |
Vacuum Insulated Pipe |
DN8 |
YES |
YES |
YES |
DN15 |
YES |
YES |
YES |
|
DN20 |
YES |
YES |
YES |
|
DN25 |
YES |
YES |
YES |
|
DN32 |
/ |
YES |
YES |
|
DN40 |
/ |
YES |
YES |
|
DN50 |
/ |
YES |
YES |
|
DN65 |
/ |
YES |
YES |
|
DN80 |
/ |
YES |
YES |
|
DN100 |
/ |
/ |
YES |
|
DN125 |
/ |
/ |
YES |
|
DN150 |
/ |
/ |
YES |
|
DN200 |
/ |
/ |
YES |
|
DN250 |
/ |
/ |
YES |
|
DN300 |
/ |
/ |
YES |
|
DN400 |
/ |
/ |
YES |
|
DN500 |
/ |
/ |
YES |
Technical Characteristic
Compensator Design Pressure | ≥4.0MPa |
Design Temperature | -196C~90℃ (LH2 & LHe:-270~90℃) |
Ambient Temperature | -50~90℃ |
Vacuum Leakage Rate | ≤1*10-10Pa*m3/S |
Vacuum Level after Guarantee | ≤0.1 Pa |
Insulated Method | High Vacuum Multi-Layer Insulation. |
Adsorbent and Getter | Yes |
NDE | 100% Radiographic Examination |
Test Pressure | 1.15 Times Design Pressure |
Medium | LO2、LN2、LAr、LH2、LHe、LEG、LNG |
Dynamic and Static Vacuum Insulated Piping System
Vacuum Insulated (VI) Piping System can be divided into Dynamic and Static VI Piping System.
l The Static VI Piping is fully completed in the manufacturing factory.
l The Dynamic VI Piping is offered a more stable vacuum state by a continuous pumping of vacuum pump system on site, and the rest of the assembly and process treatment is still in the manufacturing factory.
Dynamic Vacuum Insulated Piping System | Static Vacuum Insulated Piping System | |
Introduction | The vacuum degree of the vacuum interlayer is monitored continuously, and the vacuum pump is automatically controlled to open and close, to ensure the stability and effectiveness of vacuum degree | VJPs complete the vacuum insulation work in the manufacturing plant. |
Advantages | The vacuum retention is more stable, basically eliminate the vacuum maintenance in the future working. | More economical investment and simple on-site installation |
Vacuum Bayonet Connection Type with Clamps |
Applicative |
Applicative |
Vacuum Bayonet Connection Type with Flanges and Bolts |
Applicative |
Applicative |
Welded Connection Type |
Applicative |
Applicative |
Dynamic Vacuum Insulated Piping System: Consist of Vacuum Insulated Pipes, Jumper Hoses and Vacuum Pump System (including the vacuum pumps, solenoid valves and vacuum gauges).
Specification and Model
HL-PX-X-000-00-X
Brand
HL Cryogenic Equipment
Description
PD: Dynamic VI Pipe
PS: Static VI Pipe
Connection Type
W: Welded Type
B: Vacuum Bayonet Type with Clamps
F: Vacuum Bayonet Type with Flanges and Bolts
Nominal Diameter of Inner Pipe
010: DN10
…
080: DN80
…
500: DN500
Design Pressure
08: 8bar
16: 16bar
25: 25bar
32: 32bar
40: 40bar
Material of Inner Pipe
A: SS304
B: SS304L
C: SS316
D: SS316L
E:Other
Static Vacuum Insulated Piping System
Model |
Connection Type |
Nominal Diameter of Inner Pipe |
Design Pressure |
Material of Inner Pipe |
Standard |
Remark |
HLPSB01008X |
Vacuum Bayonet Connection Type with Clamps for Static Vacuum Insulated Piping System |
DN10, 3/8" |
8 bar
|
300 Series Stainless Steel |
ASME B31.3 |
X:
Material of Inner Pipe. A is 304, B is 304L, C is 316, D is 316L, E is other. |
HLPSB01508X |
DN15, 1/2" |
|||||
HLPSB02008X |
DN20, 3/4" |
|||||
HLPSB02508X |
DN25, 1" |
Nominal Diameter of Inner Pipe: Recommended ≤ DN25 or 1". Or selects the Vacuum Bayonet Connection Type with Flanges and Bolts (from DN10, 3/8" to DN80, 3"), Welded Connection Type VIP (from DN10, 3/8" to DN500, 20")
Nominal Diameter of Outer Pipe: Recommended by the Enterprise Standard of HL Cryogenic Equipment. It also can be produced according to requirement of the customer.
Design Pressure: Recommended ≤ 8 bar. Or selects the Vacuum Bayonet Connection Type with Flanges and Bolts (≤16 bar), Welded Connection Type (≤64 bar)
Material of Outer Pipe: Without special requirement, the material of inner pipe and outer pipe will be selected the same.
Model |
Connection Type |
Nominal Diameter of Inner Pipe |
Design Pressure |
Material of Inner Pipe |
Standard |
Remark |
HLPSF01000X |
Vacuum Bayonet Connection Type with Flanges and Bolts for Static Vacuum Insulated Piping System |
DN10, 3/8" |
8~16 bar |
300 Series Stainless Steel |
ASME B31.3 |
00:
Design Pressure. 08 is 8bar, 16 is 16bar.
X: Material of Inner Pipe. A is 304, B is 304L, C is 316, D is 316L, E is other. |
HLPSF01500X |
DN15, 1/2" |
|||||
HLPSF02000X |
DN20, 3/4" |
|||||
HLPSF02500X |
DN25, 1" |
|||||
HLPSF03200X |
DN32, 1-1/4" |
|||||
HLPSF04000X |
DN40, 1-1/2" |
|||||
HLPSF05000X |
DN50, 2" |
|||||
HLPSF06500X |
DN65, 2-1/2" |
|||||
HLPSF08000X |
DN80, 3" |
Nominal Diameter of Inner Pipe: Recommended ≤ DN80 or 3". Or selects the Welded Connection Type (from DN10, 3/8" to DN500, 20"), Vacuum Bayonet Connection Type with Clamps (from DN10, 3/8" to DN25, 1").
Nominal Diameter of Outer Pipe: Recommended by the Enterprise Standard of HL Cryogenic Equipment. It also can be produced according to requirement of the customer.
Design Pressure: Recommended ≤ 16 bar. Or selects Welded Connection Type (≤64 bar).
Material of Outer Pipe: Without special requirement, the material of inner pipe and outer pipe will be selected the same.
Model |
Connection Type |
Nominal Diameter of Inner Pipe |
Design Pressure |
Material of Inner Pipe |
Standard |
Remark |
HLPSW01000X |
Welded Connection Type for Static Vacuum Insulated Piping System |
DN10, 3/8" |
8~64 bar |
300 Series Stainless Steel |
ASME B31.3 |
00:
Design Pressure 08 is 8bar, 16 is 16bar, and 25, 32, 40, 64.
X: Material of Inner Pipe. A is 304, B is 304L, C is 316, D is 316L, E is other. |
HLPSW01500X |
DN15, 1/2" |
|||||
HLPSW02000X |
DN20, 3/4" |
|||||
HLPSW02500X |
DN25, 1" |
|||||
HLPSW03200X |
DN32, 1-1/4" |
|||||
HLPSW04000X |
DN40, 1-1/2" |
|||||
HLPSW05000X |
DN50, 2" |
|||||
HLPSW06500X |
DN65, 2-1/2" |
|||||
HLPSW08000X |
DN80, 3" |
|||||
HLPSW10000X |
DN100, 4" |
|||||
HLPSW12500X |
DN125, 5" |
|||||
HLPSW15000X |
DN150, 6" |
|||||
HLPSW20000X |
DN200, 8" |
|||||
HLPSW25000X |
DN250, 10" |
|||||
HLPSW30000X |
DN300, 12" |
|||||
HLPSW35000X |
DN350, 14" |
|||||
HLPSW40000X |
DN400, 16" |
|||||
HLPSW45000X |
DN450, 18" |
|||||
HLPSW50000X |
DN500, 20" |
Nominal Diameter of Outer Pipe: Recommended by the Enterprise Standard of HL Cryogenic Equipment. It also can be produced according to requirement of the customer.
Material of Outer Pipe: Without special requirement, the material of inner pipe and outer pipe will be selected the same.
Dynamic Vacuum Insulated Piping System
Model |
Connection Type |
Nominal Diameter of Inner Pipe |
Design Pressure |
Material of Inner Pipe |
Standard |
Remark |
HLPDB01008X |
Vacuum Bayonet Connection Type with Clamps for Static Vacuum Insulated Piping System |
DN10, 3/8" |
8 bar |
300 Series Stainless Steel |
ASME B31.3 |
X:Material of Inner Pipe.
A is 304, B is 304L, C is 316, D is 316L, E is other. |
HLPDB01508X |
DN15, 1/2" |
|||||
HLPDB02008X |
DN20, 3/4" |
|||||
HLPDB02508X |
DN25, 1" |
Nominal Diameter of Inner Pipe: Recommended ≤ DN25 or 1". Or selects the Vacuum Bayonet Connection Type with Flanges and Bolts (from DN10, 3/8" to DN80, 3"), Welded Connection Type VIP (from DN10, 3/8" to DN500, 20")
Nominal Diameter of Outer Pipe: Recommended by the Enterprise Standard of HL Cryogenic Equipment. It also can be produced according to requirement of the customer.
Design Pressure: Recommended ≤ 8 bar. Or selects the Vacuum Bayonet Connection Type with Flanges and Bolts (≤16 bar), Welded Connection Type (≤64 bar)
Material of Outer Pipe: Without special requirement, the material of inner pipe and outer pipe will be selected the same.
Power Condition: The site needs to supply power to the vacuum pumps and inform HL Cryogenic Equipment the local electricity information (Voltage and Hertz)
Model |
Connection Type |
Nominal Diameter of Inner Pipe |
Design Pressure |
Material of Inner Pipe |
Standard |
Remark |
HLPDF01000X |
Vacuum Bayonet Connection Type with Flanges and Bolts for Static Vacuum Insulated Piping System |
DN10, 3/8" |
8~16 bar |
300 Series Stainless Steel |
ASME B31.3 |
00: Design Pressure.
08 is 8bar, 16 is 16bar.
X: Material of Inner Pipe. A is 304, B is 304L, C is 316, D is 316L, E is other. |
HLPDF01500X |
DN15, 1/2" |
|||||
HLPDF02000X |
DN20, 3/4" |
|||||
HLPDF02500X |
DN25, 1" |
|||||
HLPDF03200X |
DN32, 1-1/4" |
|||||
HLPDF04000X |
DN40, 1-1/2" |
|||||
HLPDF05000X |
DN50, 2" |
|||||
HLPDF06500X |
DN65, 2-1/2" |
|||||
HLPDF08000X |
DN80, 3" |
Nominal Diameter of Inner Pipe: Recommended ≤ DN80 or 3". Or selects the Welded Connection Type (from DN10, 3/8" to DN500, 20"), Vacuum Bayonet Connection Type with Clamps (from DN10, 3/8" to DN25, 1").
Nominal Diameter of Outer Pipe: Recommended by the Enterprise Standard of HL Cryogenic Equipment. It also can be produced according to requirement of the customer.
Design Pressure: Recommended ≤ 16 bar. Or selects Welded Connection Type (≤64 bar).
Material of Outer Pipe: Without special requirement, the material of inner pipe and outer pipe will be selected the same.
Power Condition: The site needs to supply power to the vacuum pumps and inform HL Cryogenic Equipment the local electricity information (Voltage and Hertz)
Model |
Connection Type |
Nominal Diameter of Inner Pipe |
Design Pressure |
Material of Inner Pipe |
Standard |
Remark |
HLPDW01000X |
Welded Connection Type for Dynamic Vacuum Insulated Piping System |
DN10, 3/8" |
8~64 bar |
Stainless Steel 304, 304L, 316, 316L |
ASME B31.3 |
00:
Design Pressure 08 is 8bar, 16 is 16bar, and 25, 32, 40, 64. .
X: Material of Inner Pipe. A is 304, B is 304L, C is 316, D is 316L, E is other. |
HLPDW01500X |
DN15, 1/2" |
|||||
HLPDW02000X |
DN20, 3/4" |
|||||
HLPDW02500X |
DN25, 1" |
|||||
HLPDW03200X |
DN32, 1-1/4" |
|||||
HLPDW04000X |
DN40, 1-1/2" |
|||||
HLPDW05000X |
DN50, 2" |
|||||
HLPDW06500X |
DN65, 2-1/2" |
|||||
HLPDW08000X |
DN80, 3" |
|||||
HLPDW10000X |
DN100, 4" |
|||||
HLPDW12500X |
DN125, 5" |
|||||
HLPDW15000X |
DN150, 6" |
|||||
HLPDW20000X |
DN200, 8" |
|||||
HLPDW25000X |
DN250, 10" |
|||||
HLPDW30000X |
DN300, 12" |
|||||
HLPDW35000X |
DN350, 14" |
|||||
HLPDW40000X |
DN400, 16" |
|||||
HLPDW45000X |
DN450, 18" |
|||||
HLPDW50000X |
DN500, 20" |
Nominal Diameter of Outer Pipe: Recommended by the Enterprise Standard of HL Cryogenic Equipment. It also can be produced according to requirement of the customer.
Material of Outer Pipe: Without special requirement, the material of inner pipe and outer pipe will be selected the same.
Power Condition: The site needs to supply power to the vacuum pumps and inform HL Cryogenic Equipment the local electricity information (Voltage and Hertz)